Appendix B - Bluetooth Configuration Commands and Specifications System Qualification Operation Resilience Normal operation of the Bluetooth system is available in environments with radio backbones, including 802.11b, Spectrum 24, and OpenAir technologies. Specifications Temperature Operating Storage -20 °C to 60 °C (-4 °F to 140 °F) -30 °C to 70 °C (-22 °F to 158 °F) Temperature Test Results Test Range Operating Cold to Hot -20 °C to 50 °C Transition (-4 °F to 122 °F) Operating Hot to Cold 50 °C to -20 °C Transition (122 °F to -4 °F) Humidity Operating 90% Storage 90% Comments External condensation allowed, internal prohibited Speed shall not degrade 5% to 95% RH non-condensing 25 °C to 60 °C (48 °F to 140 °F) no condensation 25 °C to 60 °C (48 °F to 140 °F) no condensation Altitude -100 to 5000 meters Vibration Test Results Test Quasi-Random 3 axis Dynamic Induced Shock Operating Storage When packed Frequency Comments 12 g RMS, for 4 hours 20 g on 3 axis 1 G 5 Hz to 80 Hz 3 G 5 Hz to 80 Hz 5 to 55 Hz 6820 Series 80-Column Printer User Manual 129