Intermec 6822 6820 Series 80-Column Printer User Manual (for printers purchase - Page 138

Read Module Version, Read Local Device Address, Set Shutdown Timing, Clear Link Key Table, Syntax

Page 138 highlights

Appendix B - Bluetooth Configuration Commands and Specifications Read Module Version Syntax: V0 Description: Displays the firmware build version currently running Example: "V0" Returns: "v1yyyymmddHHMM" Note: This command responds with the requested data, only not the "ACK". Read Local Device Address Syntax: V1 Description: Displays the local device address Example 1: "v1%xx%xx%xx%xx%xx%xx" Note: This command responds with the requested data, only not the "ACK". Example 2: Sent: "V1" Received: "v1%00%2C%C6%03%45%39" Set Shutdown Timing Syntax: T0 Description: "Time" - Integer value - 0 implies never expire the timer Default: 120 Range: 0 to 270 minutes Example: "T0120" This sets the shutdown timer to 120 minutes. Clear Link Key Table Syntax: B0 Description: Clear Pair or Bonding command cleans up all of the link key and Bluetooth address combination PSKEYs. Default: None Example: "B0CLR" Clears all saved link keys. 122 6820 Series 80-Column Printer User Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Appendix B — Bluetooth Configuration Commands and Specifications
122
6820 Series 80-Column Printer User Manual
Read Module Version
Syntax:
V0<CR>
Description:
Displays the firmware build version currently running
Example:
“V0<CR>” Returns: “v1yyyymmddHHMM<CR>”
Read Local Device Address
Syntax:
V
1<CR>
Description:
Displays the local device address
Example 1:
“v1%xx%xx%xx%xx%xx%xx<CR>”
Example 2:
Sent: “V1<CR>“
Received: ”v1%00%2C%C6%03%45%39”
Set Shutdown Timing
Syntax:
T0<Time in Minutes><CR>
Description:
“Time” – Integer value – 0 implies never expire the timer
Default:
120
Range:
0 to 270 minutes
Example:
“T0120<CR>” This sets the shutdown timer to 120 minutes.
Clear Link Key Table
Syntax:
B0<CLR><CR>
Description:
Clear Pair or Bonding command cleans up all of the link key and
Bluetooth address combination PSKEYs.
Default:
None
Example:
“B0CLR<CR>” Clears all saved link keys.
Note:
This command responds with the requested data, only not the
“ACK<CR>”.
Note:
This command responds with the requested data, only not the
“ACK<CR>”.