Konica Minolta AccurioPress C6085 IC-314 User Guide - Page 116
Print and measure chart, Use G7 calibration, Measuring device, Warm up copies, Screening, Calibration
View all Konica Minolta AccurioPress C6085 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
106 Chapter 7-Managing color 2. Make sure that both the Print and measure chart option and the Use G7 calibration check box are selected, and click Next. 3. On the Print color chart screen perform the following actions: a. In the Measuring device list, select the measuring device that you want to use to measure the color chart. b. In the Warm up copies box, select the number of copies of the warm-up file that you want to print. Note: Warm up copies are not available when creating the profile using the Intelligent Quality Optimizer. c. In the Tray list, select the tray in which the paper stock for which you want to create a profile is loaded. d. In the Screening list, select the screening method for the profile. e. In the Calibration list, select the relevant calibration table. Notes: ● When creating a G7 based destination profile, the Linked calibration option is not available. ● If you are creating the profile using the Intelligent Quality Optimizer, only one copy of the profiling chart can be printed. 4. Click Print. The color measurement chart is printed.