Konica Minolta AccurioPress C6085 IC-314 User Guide - Page 42

Using the X-Rite i1iO spectrophotometer to create a calibration table, Finish, Requirements

Page 42 highlights

32 Chapter 3-Calibration 14. Click Finish. The new calibration table is saved and applied to the next job that prints, provided that the job ticket is programmed to use the paper stock that was calibrated. Using the X-Rite i1iO spectrophotometer to create a calibration table Requirements: ● Your spectrophotometer must be connected to the USB port on the IC-314 print controller. The first time that you connect the device to the IC-314 print controller, you are notified that the driver is being installed. Wait for the driver installation to finish before proceeding further. ● Before inserting the i1 into the arm of the i1iO, make sure that the i1 spectrophotometer is calibrated by placing it on its calibration plate. Refer to the spectrophotometer product documentation for more information. ● Insert the i1 spectrophotometer in the arm of the i1iO spectrophotometer and make sure that the arm is in its docking position. ● The Print queue must be ready for printing (not suspended), and the printer must be warmed up.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305

14.
Click
Finish
.
The new calibration table is saved and applied to the next job
that prints, provided that the job ticket is programmed to use
the paper stock that was calibrated.
Using the X-Rite i1iO spectrophotometer to create a calibration
table
Requirements:
Your spectrophotometer must be connected to the USB port on
the IC-314 print controller. The first time that you connect the
device to the IC-314 print controller, you are notified that the
driver is being installed. Wait for the driver installation to finish
before proceeding further.
Before inserting the i1 into the arm of the i1iO, make sure that
the i1 spectrophotometer is calibrated by placing it on its
calibration plate. Refer to the spectrophotometer product
documentation for more information.
Insert the i1 spectrophotometer in the arm of the i1iO
spectrophotometer and make sure that the arm is in its docking
position.
The Print queue must be ready for printing (not suspended),
and the printer must be warmed up.
32
Chapter 3—Calibration