Lantronix PremierWave XC PremierWave XC - User Guide - Page 54

To Con Tunnel Connect Mode Settings, Using Web Manager, Using the CLI, Using XML, Tunnel

Page 54 highlights

7:Line and Tunnel Settings Tunnel Connect Description Mode Settings Flush Serial Data Sets whether the serial Line data buffer is flushed upon a new network connection. Choices are:  Enabled = serial data buffer is flushed on network connection  Disabled = serial data buffer is not flushed on network connection (default) Block Serial Set whether Block Serial is enabled for debugging purposes. Choices are:  Enabled = If Enabled, incoming characters from the Serial Line will not be forwarded to the network. Instead, they will be buffered and will eventually flow off the Serial Line if hardware or software flow control is configured.  Disabled = this is the default setting; incoming characters from the Serial Line are sent on into the network. Any buffered characters are sent first.  Any Character = a connection is attempted when any character is read on the serial line.  Start Character = a connection is attempted when the start character for the selected tunnel is read on the serial line.  Modem Control Asserted = a connection is attempted as long as the Modem Control pin (DSR) is asserted, until a connection is made.  Modem Emulation = a connection is attempted when triggered by modem emulation AT commands. Block Network Set whether Block Network is enabled for debugging purposes. Choices are:  Enabled = If Enabled, incoming characters from the network will not be forwarded to the Serial Line. Instead, they will be buffered and will eventually flow off the network side.  Disabled = this is the default setting; incoming characters from the network are sent on into the Serial Line. Any buffered characters are sent first. Email on Connect Email on Disconnect Select an email profile number to which an email notification will be sent upon the establishment of an accept mode tunnel. Select an email profile number to which an email notification will be sent upon the disconnection of an accept mode tunnel. To Configure Tunnel Connect Mode Settings Using Web Manager  To configure the Connect Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Connect Mode. Using the CLI  To enter the Tunnel 1 Connect Mode command level: enable -> tunnel 1 -> connect Using XML  Include in your file: PremierWave XC User Guide 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109

7: Line and Tunnel Settings
PremierWave XC User Guide
54
Tunnel Connect
Mode Settings
Description
Flush Serial Data
Sets whether the serial Line data buffer is flushed upon a new network connection.
Choices are:
Enabled
= serial data buffer is flushed on network connection
Disabled
= serial data buffer is not flushed on network connection (
default
)
Block Serial
Set whether Block Serial is enabled for debugging purposes.
Choices are:
Enabled
= If Enabled, incoming characters from the Serial Line will not be forwarded
to the network.
Instead, they will be buffered and will eventually flow off the Serial
Line if hardware or software flow control is configured.
Disabled
= this is the default setting; incoming characters from the Serial Line are
sent on into the network.
Any buffered characters are sent first.
Any Character
= a connection is attempted when any character is read on the serial
line.
Start Character
= a connection is attempted when the start character for the selected
tunnel is read on the serial line.
Modem Control Asserted
= a connection is attempted as long as the Modem
Control pin (DSR) is asserted, until a connection is made.
Modem Emulation
= a connection is attempted when triggered by modem emulation
AT commands.
Block Network
Set whether Block Network is enabled for debugging purposes.
Choices are:
Enabled
= If Enabled, incoming characters from the network will not be forwarded to
the Serial Line.
Instead, they will be buffered and will eventually flow off the network
side.
Disabled
= this is the default setting; incoming characters from the network are sent
on into the Serial Line.
Any buffered characters are sent first.
Email on
Connect
Select an email profile number to which an email notification will be sent upon the
establishment of an accept mode tunnel.
Email on
Disconnect
Select an email profile number to which an email notification will be sent upon the
disconnection of an accept mode tunnel.
To Configure Tunnel Connect Mode Settings
Using Web Manager
To configure the Connect Mode for a specific tunnel, click
Tunnel
in the menu and select
Tunnel 1 -> Connect Mode
.
Using the CLI
To enter the Tunnel 1 Connect Mode command level:
enable -> tunnel 1 ->
connect
Using XML
Include in your file:
<configgroup name="tunnel connect" instance="1">