Lenovo NetVista Hardware Maintenance Manual for NetVista 6018, 6058, 6059, 626 - Page 103
on Check startup sequence
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
Message/Symptom FRU/Action Non-system disk or disk error-type message with a known-good diagnostic diskette. 1. Diskette Drive 2. System Board 3. Diskette Drive Cable 4. Riser card Drives not recognized by the Fixed Disk diagnostic 1. Remove the first drive that does not show up (e.g., you have six drives but the fixed disk test and rerun the Fixed Disk diagnostic. If the only shows three) remaining drives then show up, replace the drive you removed. Hang during Fixed Disk diagnostic 1. Remove the hard file being tested at the time of the hang. 2. Rerun the diagnostic. 3. If successful, replace the drive you removed. Other display symptoms not listed above (including blank or illegible display) 1. See "Display" on page 32 2. System Board 3. Display Power-on indicator or hard disk drive in-use light not on, but computer works correctly 1. Power Supply 2. System Board 3. LED Cables Printer problems 1. See "Printer" on page 29 Program loads from the hard disk with a known-good diagnostics diskette in the first 3.5-inch diskette drive 1. Run Setup 2. Diskette Drive 3. Diskette Drive Cable 4. System Board 5. Riser card 6. Power Supply RPL computer cannot access programs from its own hard disk. 1. If network administrator is using LCCM Hybrid RPL, check startup sequence: a. First device - network b. Second device - hard disk 2. Hard disk drive RPL computer does not RPL from server 1. Check startup sequence 2. Check the network adapter LED status Chapter 2. Types 6568/6569/6648/6649 89