Lenovo NetVista Hardware Maintenance Manual for NetVista 6018, 6058, 6059, 626 - Page 96
Hard Disk Drive ESDI, Diskette Drive
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
POST Error Code 10453Wrong drive type? 10454Sector buffer test error 10455, 10456Controller error 10459Drive diagnostic command error 10461Drive format error 10462Controller seek error 10464Hard Drive read error 10467Drive non-fatal seek error 10468Drive fatal seek error 10469Drive soft error count exceeded 10470, 10471, 10472Controller wrap error 10473Corrupt data. Low level format might be required 10480 10481ESDI drive D seek error 10482Drive select acknowledgement bad 106X1 10635 10651, 10660 106XXNot listed above 107XX FRU/Action Information only 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics Information only 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics Information only 1. Hard Disk Drive (ESDI) 2. Drive Cable 3. System Board 1. Run Enhanced Diagnostics 1. Run Enhanced Diagnostics 1. Check Configuration 2. Ethernet Adapter 1. Power-off computer, wait ten seconds then power-on the computer 2. Ethernet Adapter 1. Check Cables 2. Ethernet Adapter 1. Ethernet Adapter 1. 5.25-inch External Diskette Drive 2. 5.25-inch Diskette Drive Adapter/A 82 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648, 6649