Lenovo NetVista Hardware Maintenance Manual for NetVista 6018, 6058, 6059, 626 - Page 135
SIMM/DIMM/RIMM memory errors, SIMM/DIMM/RIMM error messages issued by the IBM PC Enhanced
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
SIMM/DIMM/RIMM memory errors SIMM/DIMM/RIMM error messages issued by the IBM PC Enhanced Diagnostics. Message 2xx-1y Failure Found A memory error was detected in SIMM socket Y. Recommended Actions Replace the SIMM in the socket identified by the last digit of the error code. Re-run the test. 2xx-2y A memory error was detected in DIMM/RIMM socket Y If the same error code occurs again, replace the system board. Replace the DIMM/RIMM in the socket identified by the last digit of the error code. Re-run the test. Corrupt BIOS Information in BIOS is not as expected. Not able to find expected DMI information from BIOS. If the same error code occurs again, replace the system board or where memory is on the processor card, replace the processor card. Reflash the BIOS. Perform boot block recovery. Replace the system board. Test aborted by user Memory controller chipset vendor ID does not match expected value. User stopped test. Restart test. Note: Y is the SIMM/DIMM/RIMM socket number. Use the System Board Layout section in the latest Hardware Maintenance Manual (HMM) to reference the memory sockets. Chapter 3. Types 6058/6059/6269/6578/6579 121