Lenovo NetVista Hardware Maintenance Manual for NetVista 6018, 6058, 6059, 626 - Page 18
Device on IRQ2
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Diagnostic Error Code FRU/Action 001-199-XXXSystem test failed, cause unknown 1. Go to the ″Undetermined problems″ section 2. Flash the system and re-test 3. Replace component under function test 001-250-XXXSystem ECC error 1. System board 001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXXSystem DMA error 1. System board 001-260-XXX 001-264-XXXSystem IRQ error 1. System board 001-268-XXXSystem IRQ1 failure 1. Device on IRQ1 2. System board 001-269-XXXSystem IRQ2 failure 1. Device on IRQ2 2. System board 001-270-XXXSystem IRQ3 failure 1. Device on IRQ3 2. System board 001-271-XXXSystem IRQ4 failure 1. Device on IRQ4 2. System board 001-272-XXXSystem IRQ5 failure 1. Device on IRQ5 2. System board 001-273-XXXSystem IRQ6(diskette drive) failure 1. Diskette Cable 2. Diskette drive 3. System board 001-274-XXXSystem IRQ7 failure 1. Device on IRQ7 2. System board 001-275-XXXSystem IRQ8 failure 1. Device on IRQ8 2. System board 001-276-XXXSystem IRQ9 failure 1. Device on IRQ9 2. System board 001-277-XXXSystem IRQ10 failure 1. Device on IRQ10 2. System board 001-278-XXXSystem IRQ11 failure 1. Device on IRQ11 2. System board 4 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648, 6649