Lenovo NetVista Hardware Maintenance Manual (HMM) for NetVista 2284 systems - Page 76
Should Be Empty But EISA, Press A Key To Reboot
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Table 2-1 POST Error Codes and Messages List NOTE: To diagnose a problem, first find the BIOS error messages or codes in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause. BIOS Error Codes, Messages Action/FRU Memory Address Error at ....... Memory Parity Error at Memory Size Has Changed Since Last Boot Memory Verify Error at............ RAM Parity Error-Checking For Segment.. 1. Insert the memory modules in the DIMM sockets properly, then reboot the system 2. Memory module. See "005 -" on page 65 to replace memory module 3. System board Offending Address Not Found Offending Segment 1. Enter Configuration/ Setup Utility and load the default settings. 2. Remove all adapter cards that are NOT factoryinstalled, then reboot the system. 3. System board Press A Key To Reboot 1. Message Only Should Be Empty But EISA Board Found Please Run EISA Configuration Utility 1. No ESIA slot available Should Have EISA Board But Not Found Please Run EISA Configuration Utility 1. No ESIA slot available Slot Not Empty 1. No ESIA slot available System Halted, (CTRL-ALT- 1. Message Only DEL) To Reboot..... Wrong Board in Slot Please Run EISA Configuration Utility 1. No ESIA slot available 42 IBM Desktop System HMM