Setup Utility and Load, Hard Disk Drive, Error Symptoms, Action/FRU
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Error Symptoms Action/FRU Diskette drive test failed. 1. Diskette 2. Diskette drive 3. Diskette drive cable 4. System board Hard Disk Drive NOTE: Ensure hard disk drive is configured correctly in Configuration/Setup Utility, cable/jumper are set correctly before diagnosing any hard disk drive problems. Hard disk drive test failed. 1. Enter Configuration/ Setup Utility and Load default settings. 2. Hard disk drive cable. 3. Hard disk drive. 4. System board. Hard disk drive format error. 1. Enter Configuration/ Setup Utility and Load default settings. 2. Hard disk drive cable. 3. Hard disk drive. 4. System board. Hard disk drive write error. 1. Enter Configuration/ Setup Utility and Load default settings. 2. Hard disk drive. Hard disk drive LED fails to light, but system operates normally. 1. With the system power on, measure the voltage of hard disk LED connector CN6. The reading should be: CN6 HDD Idle /Active pin-1 pin-1 +5Vdc/ pin-2 pin-2 +5Vdc/0Vdc pin-3 pin-3 +5Vdc/0Vdc pin-4 pin-4 +5Vdc/ - 2. See "System Board Jumpers and Connectors" on page 109. 3. Hard drive LED cable. 48 IBM Desktop System HMM