Lenovo ThinkServer RD240 Hardware Maintenance Manual - Page 84

Connect the other end of the two 400 mm 15.75 inches mini SAS signal cables to the backplane

Page 84 highlights

7. Position the RAID controller near the riser card assembly. Ensure that the left edge of the RAID controller is inserted into the notch of the RAID card retention bracket 1 , and then firmly insert the RAID controller straight down into the PCI card slot 1 2 until it is securely seated. Then install the screw 3 to secure the RAID controller. Figure 49. Installing the RAID controller into the PCI card slot 1 on the riser card assembly Note: There are three PCI card slots on the riser card assembly as shown in the illustration. The PCI card slot 1 2 is for RAID cards only. For more information about the PCI card slots, see "Installing a PCI card" on page 55. 8. Install the riser card with the RAID controller into an appropriate PCI card slot on the system board. 9. Connect the other end of the two 400 mm (15.75 inches) mini SAS signal cables to the backplane of your server. Figure 50. Mini SAS signal cable connectors on the backplane a. For one mini SAS signal cable, connect the other end to the mini SAS signal cable connector 2 on the backplane. b. For the other mini SAS signal cable, connect the other end to the mini SAS signal cable connector 1 on the backplane. 72 ThinkServer RD240 Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

7. Position the RAID controller near the riser card assembly. Ensure that the left edge of the RAID controller
is inserted into the notch of the RAID card retention bracket
1
, and then firmly insert the RAID controller
straight down into the PCI card slot 1
2
until it is securely seated. Then install the screw
3
to secure the
RAID controller.
Figure 49. Installing the RAID controller into the PCI card slot 1 on the riser card assembly
Note:
There are three PCI card slots on the riser card assembly as shown in the illustration. The PCI
card slot 1
2
is for RAID cards only. For more information about the PCI card slots, see “Installing a
PCI card” on page 55.
8. Install the riser card with the RAID controller into an appropriate PCI card slot on the system board.
9. Connect the other end of the two 400 mm (15.75 inches) mini SAS signal cables to the backplane of
your server.
Figure 50. Mini SAS signal cable connectors on the backplane
a.
For one mini SAS signal cable, connect the other end to the mini SAS signal cable connector
2
on
the backplane.
b. For the other mini SAS signal cable, connect the other end to the mini SAS signal cable connector
1
on the backplane.
72