RS485 setup RS485 SETUP, Data port setup DATA PORT SETUP, Unit Address System, Baud Rate, Data Bit

Page 41 highlights

RS485 setup (RS485 SETUP) Refer to the step (7) in 2.5. Data port setup (DATA PORT SETUP) The settings relating to the serial data communication can be configured on "DATA PORT SETUP" of "COMMUNICATION SETUP" on the "WJ-RT208 SETUP MENU". (1) Press the [MENU] button. The "WJ-RT208 SETUP MENU" will be displayed. WJ-RT208 SETUP MENU SYSTEM MANAGEMENT SEARCH REC&EVENT SETUP PTZ SETUP CAMERA SETUP COMMUNICATION SETUP REPORT USER INFORMATION DATA MANAGEMENT (2) Move the cursor onto "COMMUNICATION SETUP" and press the [SET] button. The "COMMUNICATION SETUP" menu will be displayed. COMMUNICATION SETUP NETWORK SETUP RS485 SETUP DATA PORT SETUP (3) Move the cursor onto "DATA PORT SETUP" and press the [SET] button. The "DATA PORT SETUP" menu will be displayed. DATA PORT SETUP Unit Address (System) Baud Rate Data Bit Parity Stop Bit Retry Timing Alarm Data Channel No. 001 9600 8 None 1 Off 1s Set OK Cancel (4) Configure the following setup items. • "Unit Address (System)" A unit address (System) is a unique number assigning to PS·Data devices. The addresses must be unique to identify system devices when connecting multiple devices compatible with PS·Data. Numbers, "001"-"099", are to be assigned as the unit addresses to the system devices. • "Baud Rate" Select the communication speed for data transmission with a connected device from the following. 2 400/4 800/9 600/19 200/38 400 bps • "Data Bit" It is impossible to change the value for this setting. 8 (bit) • "Parity" Select a method to check a transmission error at communication from the following. "None": No parity check "Even": Even parity "Odd": Odd parity • "Stop Bit" Select a stop bit from the following. 1 bit/2 bit • "Retry Timing" Select a retransmission interval for when data reception is not confirmed from the following. OFF/100 ms/200 ms/400 ms/1 000 ms • "Alarm Data" Select a method to inform the connected controller of an event occurrence from the following. "Off": Does not function. "0s": Informs the controller every time an event is detected. "1s/5s": Informs the controller when a specified time has passed after detecting an event. • "Channel No." It is possible to assign a number to each camera channel to operate cameras using the controller compatible with PS·Data. Do the following to assign numbers to the camera channels. (1) Move the cursor onto "Channel No." and press the [SET] button. The "Channel No." menu will be displayed. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

41
RS485 setup (RS485 SETUP)
Refer to the step (7) in 2.5.
Data port setup (DATA PORT SETUP)
The settings relating to the serial data communication can
be configured on "DATA PORT SETUP" of "COMMUNICA-
TION SETUP" on the "WJ-RT208 SETUP MENU".
(1) Press the [MENU] button. The "WJ-RT208 SETUP
MENU" will be displayed.
(2) Move the cursor onto "COMMUNICATION SETUP" and
press the [SET] button.
The "COMMUNICATION SETUP" menu will be dis-
played.
(3) Move the cursor onto "DATA PORT SETUP" and press
the [SET] button.
The "DATA PORT SETUP" menu will be displayed.
(4)
Configure the following setup items.
"Unit Address (System)"
A unit address (System) is a unique number assigning
to PS·Data devices. The addresses must be unique to
identify system devices when connecting multiple
devices compatible with PS·Data.
Numbers, "001"-"099", are to be assigned as the unit
addresses to the system devices.
"Baud Rate"
Select the communication speed for data transmission
with a connected device from the following.
2 400/4 800/9 600/19 200/38 400 bps
"Data Bit"
It is impossible to change the value for this setting.
8 (bit)
"Parity"
Select a method to check a transmission error at com-
munication from the following.
"None":
No parity check
"Even":
Even parity
"Odd":
Odd parity
"Stop Bit"
Select a stop bit from the following.
1 bit/2 bit
"Retry Timing"
Select a retransmission interval for when data reception
is not confirmed from the following.
OFF/100 ms/200 ms/400 ms/1 000 ms
"Alarm Data"
Select a method to inform the connected controller of
an event occurrence from the following.
"Off":
Does not function.
"0s":
Informs the controller every time an event is
detected.
"1s/5s":
Informs the controller when a specified time
has passed after detecting an event.
"Channel No."
It is possible to assign a number to each camera chan-
nel to operate cameras using the controller compatible
with PS·Data.
Do the following to assign numbers to the camera chan-
nels.
(1) Move the cursor onto "Channel No." and press the
[SET] button.
The "Channel No." menu will be displayed.
COMMUNICATION SETUP
NETWORK SETUP
RS485 SETUP
DATA PORT SETUP
WJ-RT208 SETUP MENU
SYSTEM MANAGEMENT
SEARCH
REC&EVENT SETUP
PTZ SETUP
CAMERA SETUP
COMMUNICATION SETUP
REPORT
USER INFORMATION
DATA MANAGEMENT
DATA PORT SETUP
001
Unit Address (System)
9600
Baud Rate
8
Data Bit
None
Parity
1
Stop Bit
Off
Retry Timing
1s
Alarm Data
Set
Channel No.
OK
Cancel