Panasonic WJRT208 WJRT208 User Guide - Page 53
Camera Setup CAMERA SETUP, Communication Setup COMMUNICATION SETUP, 1 Network Setup NETWORK SETUP
View all Panasonic WJRT208 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
5. Camera Setup (CAMERA SETUP) Setting item "Channel No." "CH Enable" "Mask Area" "Mask Enable" "PTZ Protocol" "Rec. Reserve" "Channel Name" Default setting 1 "On" - "Off" "PANASONIC" 000 "CH1" Available values 1 - 8 "Off/On" - "Off/On" "PANASONIC/TYPE 1/TYPE 2/TYPE 3/TYPE 4" 000 - 200 "en: 10 letters, em: 5 letters" Note: The parameters for this unit can be defined for each channel. 6. Communication Setup (COMMUNICATION SETUP) 6.1 Network Setup (NETWORK SETUP) Setting item "IP Address" "Subnet Mask" "Gateway" "Server Port" "Protocol" "Alarm Center IP" "Alarm Port" "Alarm Enable" "Line Speed" Default setting 192.168.000.088 255.255.255.000 192.168.000.001 2000 "TCP" 192.168.000.188 4000 "Off" "Auto Mode" Available values 001.000.000.000 - 255.255.255.255 000.000.000.000 - 255.255.255.254 001.000.000.000 - 255.255.255.255 1024 - 9999 "TCP/UDP/MCAST" 001.000.000.000 - 255.255.255.255 1024 - 9999 "Off/On" "Auto Mode/10M Half/10M Full/100M Half/100M Full" 6.2 RS485 Setup (RS485 SETUP) Setting item "Baud Rate" "Data Bit" "Parity" "Stop Bit" Default setting 19200 8 "None" 1 Available values 2400/4800/9600/19200/38400 - (FIX) - (FIX) - (FIX) 6.3 Data port setup (DATA PORT SETUP) Setting item "Unit Address (System)" "Baud Rate" "Data Bit" "Parity" "Stop Bit" "Retry Timing" "Alarm Data" "Channel No." Default setting 001 9600 8 "None" 1 "Off" "1s" - Available values 001 - 099 2400/4800/9600/19200/38400 - (FIX) "None/Even/Odd" 1/2 "Off/100ms/200ms/400ms/1000ms" "Off/0s/1s/5s" - 53