Sharp MX-2310U Installation Manual - Page 45
MX-FN17 (FINISHER), 1. Unpacking, A. Check the packed items, 2. Installation, A. Removal of
View all Sharp MX-2310U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
[M6X-]2310MU X-FN17 (FINISHER) 1. Unpacking A. Check the packed items 1 2 3 4 5 Service Manual 2. Installation Before installation, be sure to turn both the operation and main power switches off and disconnect the power plug from the power outlet. Make double sure that the data lamp on the operation panel does not light up or blink when performing installation. A. Removal of the paper holding arm and the paper exit full detection actuator 1) Remove the paper holding arm. The paper holding arm must be removed together with the paper holding arm holder. Since the paper holding arm is easy to remove alone, be careful not to leave the paper holding arm holder unremoved. 6 7 8 9 10 11 12 13 14 15 16 17 18 19 No. Name 1 Finisher 2 Attachment 3 Blinding bottom plate 4 Front rail guide 5 Path guide 6 Open/Close cover 7 Left rear cover 8 Punch F cover 9 Fulcrum upper cover 10 Take-up roller 11 Screw (M4 x 10 S tight) 12 Screw (M3 x 6 S tight, with flange) 13 Screw (M4 x 6 S tight) 14 Screw (M3 x 6 S tight) 15 Clip 16 Fulcrum shaft 17 Staple position label (For the scanner) 18 Staple position label (For the RSPF) 19 Safety cover 20 Protection sheet 20 Quantity 1 1 1 1 1 1 1 1 1 1 1 4 5 3 1 1 1 1 1 1 2) Remove the paper exit full detection actuator. MX-2310U MX-FN17 (FINISHER) 6 - 1