Yamaha DGX-650 Owner's Manual - Page 68

Category, Function, Range/Settings, Default Value, Description, DGX-650, Owner's Manual

Page 68 highlights

The Functions Category Function Reverb Type Chorus Type DSP DSP Type Damper Resonance Effect Sustain MASTER EQ Type Output Gain I. A. Control I. A. Control Depth Harmony (page 27) Harmony Type Harmony Volume PC (USB TO PC Mode HOST terminal) Local External Clock MIDI*** Keyboard Out Style Out Song Out Initial Setup Metronome (page 25) Time Signature Numerator Time Signature Denominator Bell Metronome Volume Range/Settings 01-36 01-45 ON/OFF 001-239 ON/OFF ON/OFF 1 (Normal)/ 2 (Piano)/ 3 (Soft)/ 4 (Bright)/ 5 (Powerful) Headphones/ Line Out ON/OFF -3-+3 01-26 000-127 PC1/PC2/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON Default Value Description ** Refer to page 50. ** Refer to page 50. * Refer to page 51. * Refer to page 51. ON This effect is applied only to Voice 001 (Main Voice) or Voice 001 used in Track 1 of the Song. Refer to pages 16 and 18. OFF Refer to page 52. Normal Refer to page 54. Headphones Refer to page 55. ON 0 * * OFF ON OFF ON OFF OFF - Refer to page 56. Refer to page 56. Determines the Harmony type. Determines the volume of the Harmony effect. Optimizes the MIDI settings when transmitting or receiving the performance data between the computer and the instrument (page 69). Determines whether the instrument's keyboard controls the internal tone generator (ON) or not (OFF). When you record your keyboard performance to the application software on the computer via MIDI, set this parameter to OFF. Determines whether the instrument synchronizes to the internal clock (OFF) or an external clock (ON). When you record your keyboard performance to the application software on the computer via MIDI, set this parameter to ON. Determines whether MIDI messages generated via keyboard performance are transmitted (ON) or not (OFF) from the USB TO HOST terminal. Determines whether MIDI messages generated via Style playback are transmitted (ON) or not (OFF) from the USB TO HOST terminal. Determines whether MIDI messages generated via Song playback are transmitted (ON) or not (OFF) from the USB TO HOST terminal. Lets you send the data of the panel settings to a computer. Press [+] to send, or press [-] to cancel during sending. This operation should be done immediately after starting the Recording operation on the computer. 1-60 ** Determines the time signature of the Metronome. 2/4/8/16 ON/OFF 000-127 ** Determines the length of each metronome beat. ON Determines whether a bell accent will be sounded (ON) or not (OFF). 100 Determines the volume of the Metronome. Reference 68 DGX-650 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

The Functions
DGX-650
Owner’s Manual
68
Reference
Effect
Reverb Type
01–36
**
Refer to page 50.
Chorus Type
01–45
**
Refer to page 50.
DSP
ON/OFF
*
Refer to page 51.
DSP Type
001–239
*
Refer to page 51.
Damper Resonance
ON/OFF
ON
This effect is applied only to Voice 001 (Main Voice) or Voice
001 used in Track 1 of the Song. Refer to pages 16 and 18.
Sustain
ON/OFF
OFF
Refer to page 52.
MASTER EQ Type
1 (Normal)/
2 (Piano)/
3 (Soft)/
4 (Bright)/
5 (Powerful)
Normal
Refer to page 54.
Output Gain
Headphones/
Line Out
Headphones
Refer to page 55.
I. A. Control
ON/OFF
ON
Refer to page 56.
I. A. Control Depth
-3–+3
0
Refer to page 56.
Harmony
(page 27)
Harmony Type
01–26
*
Determines the Harmony type.
Harmony Volume
000–127
*
Determines the volume of the Harmony effect.
PC
(USB TO
HOST terminal)
PC Mode
PC1/PC2/OFF
OFF
Optimizes the MIDI settings when transmitting or receiving
the performance data between the computer and the instru-
ment (page 69).
MIDI***
Local
ON/OFF
ON
Determines whether the instrument’s keyboard controls the
internal tone generator (ON) or not (OFF). When you record
your keyboard performance to the application software on
the computer via MIDI, set this parameter to OFF.
External Clock
ON/OFF
OFF
Determines whether the instrument synchronizes to the
internal clock (OFF) or an external clock (ON). When you
record your keyboard performance to the application soft-
ware on the computer via MIDI, set this parameter to ON.
Keyboard Out
ON/OFF
ON
Determines whether MIDI messages generated via key-
board performance are transmitted (ON) or not (OFF) from
the USB TO HOST terminal.
Style Out
ON/OFF
OFF
Determines whether MIDI messages generated via Style
playback are transmitted (ON) or not (OFF) from the USB
TO HOST terminal.
Song Out
ON/OFF
OFF
Determines whether MIDI messages generated via Song
playback are transmitted (ON) or not (OFF) from the USB
TO HOST terminal.
Initial Setup
ON
Lets you send the data of the panel settings to a computer.
Press [+] to send, or press [-] to cancel during sending. This
operation should be done immediately after starting the
Recording operation on the computer.
Metronome
(page 25)
Time Signature
Numerator
1–60
**
Determines the time signature of the Metronome.
Time Signature -
Denominator
2/4/8/16
**
Determines the length of each metronome beat.
Bell
ON/OFF
ON
Determines whether a bell accent will be sounded (ON) or
not (OFF).
Metronome Volume
000–127
100
Determines the volume of the Metronome.
Category
Function
Range/Settings
Default Value
Description