ZyXEL U-1496S Plus User Guide - Page 53

CONNECT Link speed/ARQ/*Error control level - X7

Page 53 highlights

+ 12 CONNECT 9600 + 14 CONNECT 19200 + 15 CONNECT 7200 + 16 CONNECT 12000 + 17 CONNECT 14400 + 18 CONNECT 16800 + 19 CONNECT 38400 20 CONNECT 57600 21 CONNECT 76800 - 0 0 0 0 + + 0 0 0 0 + + 0 0 0 0 + + 0 0 0 0 + + 0 0 0 0 + + 0 0 0 0 + + 0 0 0 0 + - 0 0 0 0 + - 0 0 0 0 + - Notes: +: If error control result codes enabled (X5, X6, or X7), the result message will be formatted as: CONNECT DTE speed/Link speed/*Error control level - X5 CONNECT Link speed/ARQ - X6 CONNECT Link speed/ARQ/*Error control level - X7 where ARQ means Automatic Retransmission reQuest type of error control is enabled. *: Data Compression included. /SREJ is appended if V.42 with selective reject is connected. **: When more than one type of Distinctive Ring is turned on (S40b3-6), "RING n" will be reported, n=Ring type (1-4). ***: Use S42b6 to disable "RINGING" result code. Examples: For X5 - CONNECT 38400/V.32 9600T/MNP5 CONNECT 57600/V.32b 14400/V.42b Error control level is from NONE to V.42b. For X6 - CONNECT 9600/ARQ CONNECT 14400/ARQ Error control level is either ARQ or not given at all. For X7 - CONNECT 9600/ARQ/MNP5 CONNECT 14400/ARQ/V.42b Use S35.7=1 to enable the following numerical result codes when an error control connection is made. ATV0 Connect Speed Result Code With Error Control 30 CONNECT 31 CONNECT 1200 32 CONNECT 2400 33 CONNECT 4800

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

+
12
CONNECT 9600
0
0
0
0
+
+
+
14
CONNECT 19200
0
0
0
0
+
+
+
15
CONNECT 7200
0
0
0
0
+
+
+
16
CONNECT 12000
0
0
0
0
+
+
+
17
CONNECT 14400
0
0
0
0
+
+
+
18
CONNECT 16800
0
0
0
0
+
+
+
19
CONNECT 38400
0
0
0
0
+
-
-
20
CONNECT 57600
0
0
0
0
+
-
-
21
CONNECT 76800
0
0
0
0
+
-
-
Notes:
+: If error control result codes enabled (X5, X6, or X7), the result message will be
formatted as:
CONNECT DTE speed/Link speed/*Error control level - X5
CONNECT Link speed/ARQ - X6
CONNECT Link speed/ARQ/*Error control level - X7
where ARQ means Automatic Retransmission reQuest type of error control is
enabled.
*: Data Compression included. /SREJ is appended if V.42 with selective reject is
connected.
**: When more than one type of Distinctive Ring is turned on (S40b3-6), "RING
n" will be reported, n=Ring type (1-4).
***: Use S42b6 to disable "RINGING" result code.
Examples:
For X5 -
CONNECT 38400/V.32 9600T/MNP5
CONNECT 57600/V.32b 14400/V.42b
Error control level is from NONE to V.42b.
For X6 -
CONNECT 9600/ARQ
CONNECT 14400/ARQ
Error control level is either ARQ or not given at all.
For X7 -
CONNECT 9600/ARQ/MNP5
CONNECT 14400/ARQ/V.42b
Use S35.7=1 to enable the following numerical result codes when an error control
connection is made.
ATV0
Connect Speed
Result Code
With Error Control
30
CONNECT
31
CONNECT 1200
32
CONNECT 2400
33
CONNECT 4800