ZyXEL U-1496S Plus User Guide - Page 58

View password table.

Page 58 highlights

Note: These commands *Hn and *HS need supervisory password checking. Any character can be entered in the password (0-255). Maximum password length is eight. + *I0 AT command set (Default). *I1 V.25bis command set. *I2 Dumb mode. Note: Enter RST command in V.25bis mode will revert modem to asynchronous AT command mode. + *L0 Panel key normal (Default). *L1 Panel key locked. + *M0 Leased line auto-handshake on originate mode (Default). *M1 Leased line auto-handshake on answer mode. *P0-15 Set leased line transmission power level, range from 0 dBm to -15dBm (Default = -9dBm). Range from -12dBm to -27dBm if S35 bit 3 is set. *Q0 No response to poor signal quality. *Q1 Retrain action taken if signal quality is poor. + *Q2 Adaptive rate; auto fall-back or fall-forward (Default). *Q3 Disconnect for poor signal quality. *Rab Read remote profile b to local profile a. a= 0-3, local user profile number. b= 0-3, remote user profile number. 4, remote active configuration. 5, remote factory default. Note: The command *Rab only works when modem is on-line, no matter what kind of connection. + *S0 Secondary channel disabled (Default). *S1 Secondary channel enabled. *T Display last caller ID message. *V View password table. Note: The command *V needs supervisory password checking. *Wab Write local configuration profile a to remote user profile b and reset remote modem from that profile. a= 0-3, local user profile number. 4, local active configuration. 5, local factory default settings. b= 0-3, remote user profile number. Note: The command *Wab only works when modem is on-line, no matter what kind of connection.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

Note: These commands *Hn and *HS need supervisory password checking. Any character can
be entered in the password (0-255). Maximum password length is eight.
+
*I0
AT command set (Default).
*I1
V.25bis command set.
*I2
Dumb mode.
Note: Enter RST command in V.25bis mode will revert modem to asynchronous AT command
mode.
+
*L0
Panel key normal (Default).
*L1
Panel key locked.
+
*M0
Leased line auto-handshake on originate mode (Default).
*M1
Leased line auto-handshake on answer mode.
*P0-15
Set leased line transmission power level, range from 0 dBm to -15dBm (Default
= -9dBm). Range from -12dBm to -27dBm if S35 bit 3 is set.
*Q0
No response to poor signal quality.
*Q1
Retrain action taken if signal quality is poor.
+
*Q2
Adaptive rate; auto fall-back or fall-forward (Default).
*Q3
Disconnect for poor signal quality.
*Rab
Read remote profile b to local profile a.
a=
0-3,
local user profile number.
b=
0-3,
remote user profile number.
4,
remote active configuration.
5,
remote factory default.
Note: The command *Rab only works when modem is on-line, no matter what kind of connection.
+
*S0
Secondary channel disabled (Default).
*S1
Secondary channel enabled.
*T
Display last caller ID message.
*V
View password table.
Note: The command *V needs supervisory password checking.
*Wab
Write local configuration profile a
to remote user profile b
and reset remote modem
from that profile.
a=
0-3,
local user profile number.
4,
local active configuration.
5,
local factory default settings.
b=
0-3,
remote user profile number.
Note: The command *Wab only works when modem is on-line, no matter what kind of
connection.