ZyXEL U-1496S Plus User Guide - Page 78

Report remote ID response CIG

Page 78 highlights

+FET=n End the page or document command n=0 More pages; same document n=1 End of document; another document follows n=2 No more pages or documents n=4 Procedure interrupt: another page follows n=5 Procedure interrupt: end of document, another document follows n=6 Procedure interrupt: end of document +FLID="string" Local ID string parameter +FLPL=n Document for polling command n=0 Indicate that the DTE has no document for polling n=1 Indicate document available for polling +FMDL? Request DCE model +FMFR? Request DCE manufacturer +FPTS=n Page transfer status n=1 Received page good n=2 Page bad; retrain requested n=3 Page good; retrain requested n=4 Page bad; procedure interrupt requested n=5 Page good; procedure interrupt requested +FNS="" Non-standard frame FIF octet string +FREV? Request DCE revision +FSPL=n Enable polling command n=0 Disable polling n=1 Enable polling All other +F commands are not supported but the modem will respond OK. In many cases this means "don't care". See PN 2388 for command details. The Class 2 Command Responses Response Function and Description +FCIG:"String" Report remote ID response CIG +FCFR Confirmation to receive prompt +FCON Facsimile connection response +FCSI:"String" Report remote ID response CSI +FDCS:vr,br,wd,ln,df,ec,bf,st Report session parameters response; refer to +FDCC=.... command. +FDIS:vr,br,wd,ln,df,ec,bf,st Report remote capabilities response; refer to +FDCC=.... command. +FDTC:vr,br,wd,ln,df,ec,bf,st Report remote capabilities response; refer to +FDCC=.... command. +FET:n Post page message response; refer to +FET=n command. +FHNG:nnn Call termination status response. nnn=00 Normal and proper end of connection. nnn=10 Transmit error on phase A hangup code. nnn=20 Transmit error on phase B hangup code. nnn=40 Transmit error on phase C hangup code. nnn=50 Transmit error on phase D hangup code. nnn=70 Receive error on phase B hangup code. nnn=90 Receive error on phase C hangup code. nnn=100 Receive error on phase D hangup code. +FNSC:"HEX string" Report the non-standard facilities command frame. For example, the polling security ID. +FNSF:"HEX string" Report the non-standard facilities frame response. +FPOLL Remote polling indication.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

+FET=n
End the page or document command
n=0
More pages; same document
n=1
End of document; another document follows
n=2
No more pages or documents
n=4
Procedure interrupt: another page follows
n=5
Procedure interrupt: end of document, another document follows
n=6
Procedure interrupt: end of document
+FLID="string"
Local ID string parameter
+FLPL=n
Document for polling command
n=0
Indicate that the DTE has no document for polling
n=1
Indicate document available for polling
+FMDL?
Request DCE model
+FMFR?
Request DCE manufacturer
+FPTS=n
Page transfer status
n=1
Received page good
n=2
Page bad; retrain requested
n=3
Page good; retrain requested
n=4
Page bad; procedure interrupt requested
n=5
Page good; procedure interrupt requested
+FNS="<string of Hex>"
Non-standard frame FIF octet string
+FREV?
Request DCE revision
+FSPL=n
Enable polling command
n=0
Disable polling
n=1
Enable polling
All other +F commands are not supported but the modem will respond OK. In many cases this
means "don't care". See PN 2388 for command details.
The Class 2 Command Responses
Response
Function and Description
+FCIG:"String"
Report remote ID response CIG
+FCFR Confirmation to receive prompt
+FCON Facsimile connection response
+FCSI:"String"
Report remote ID response CSI
+FDCS:vr,br,wd,ln,df,ec,bf,st
Report session parameters response; refer to +FDCC=
....
command.
+FDIS:vr,br,wd,ln,df,ec,bf,st
Report remote capabilities response; refer to +FDCC=
....
command.
+FDTC:vr,br,wd,ln,df,ec,bf,st
Report remote capabilities response; refer to +FDCC=
....
command.
+FET:n Post page message response; refer to +FET=n command.
+FHNG:nnn
Call termination status response.
nnn=00 Normal and proper end of connection.
nnn=10 Transmit error on phase A hangup code.
nnn=20 Transmit error on phase B hangup code.
nnn=40 Transmit error on phase C hangup code.
nnn=50 Transmit error on phase D hangup code.
nnn=70 Receive error on phase B hangup code.
nnn=90 Receive error on phase C hangup code.
nnn=100
Receive error on phase D hangup code.
+FNSC:"HEX string"
Report the non-standard facilities command frame. For example, the
polling security ID.
+FNSF:"HEX string"
Report the non-standard facilities frame response.
+FPOLL
Remote polling indication.