ZyXEL U-1496S Plus User Guide - Page 85
Supported Commands For Voice Mode Operation
View all ZyXEL U-1496S Plus manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
FLOW CONTROL Software XON/XOFF flow control is used. SUPPORTED COMMANDS FOR VOICE MODE OPERATION AT+FCLASS= This command selects a DCE mode as follows: = 0 (Default), Data mode. = 2, Fax mode. = 8, Voice mode. Result codes: OK: ERROR: The DCE issues this result code if DCE accepts this command. The DCE issues this result code if is not permitted. AT+FCLASS? DCE will return current mode setting, followed by the OK result code. AT+FCLASS=? DCE will return permitted modes. The response is: 0,2,8 OK with between each line. ATA (with AT+FCLASS=8) This command causes DCE to answer the phone. DCE will return the VCON result code immediately. ATD (with AT+FCLASS=8) This command causes the DCE to dial a phone number. Result codes: VCON: The DCE issues this result code when the DCE has determined that the remote station is off hook. NO CARRIER: The DCE issues this result code when the DCE has continuously detected ringbacks for the amount of time specified in S7. BUSY: The DCE issues this result code when the DCE detects a busy tone. RINGING: The DCE issues this result code when the DCE detects a ringback signal.