ZyXEL U-1496S Plus User Guide - Page 87

Activity Timer

Page 87 highlights

OK: ERROR: The DCE issues this result code if DCE accepts this command. The DCE issues this result code if parameter is out of range. AT+VBT? DCE will return current beep duration setting, followed by the OK result code. AT+VBT=? DCE will return permitted values of beep duration. The response is: 1-255 OK with between each line. AT+VIP This command causes the DCE to initialize all the voice parameters to the default settings as follows: Parameter: Value: see also Compression method: 2-bit ADPCM Silence threshold: 16 +VSD Activity Timer: 7 sec. Silence interval: 7 sec. +VSD Ringback goes away timer: Ringback never appeared timer: Default beep tone duration: +VSM 7 sec. 5.7 sec. 1 sec. +VRA +VRN +VBT/+VTS Result codes: OK: The DCE issues this result code if DCE accepts this command. ERROR: The DCE issues this result code if the DCE is not connected to at least one voice I/O device. AT+VLS= This command causes the DCE to select a voice I/O device. The permitted is as follows: 0: 2: 8: jack.) 16: disconnect all I/O devices Telco line External Mic. (Connect a microphone or telephone set to the dial-up line RJ11 Internal speaker Result codes: OK: ERROR: The DCE issues this result code if DCE accepts this command. The DCE issues this result code if is not permitted.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

OK:
The DCE issues this result code if DCE accepts this command.
ERROR:
The DCE issues this result code if <value> parameter is out of range.
AT+VBT?
DCE will return current beep duration setting, followed by the OK result code.
AT+VBT=?
DCE will return permitted values of beep duration. The response is:
1-255
OK
with <CR><LF> between each line.
AT+VIP
This command causes the DCE to initialize all the voice parameters to the default settings
as follows:
Parameter:
Value: see also
Compression method:
2-bit ADPCM
+VSM
Silence threshold:
16
+VSD
Activity Timer:
7 sec.
Silence interval:
7 sec.
+VSD
Ringback goes away timer:
7 sec.
+VRA
Ringback never appeared timer:
5.7 sec.
+VRN
Default beep tone duration:
1 sec.
+VBT/+VTS
Result codes:
OK:
The DCE issues this result code if DCE accepts this command.
ERROR:
The DCE issues this result code if the DCE is not connected to at least one
voice I/O device.
AT+VLS=<device>
This command causes the DCE to select a voice I/O device.
The permitted <device> is as follows:
0:
disconnect all I/O devices
2:
Telco line
8:
External Mic. (Connect a microphone or telephone set to the dial-up line RJ11
jack.)
16:
Internal speaker
Result codes:
OK:
The DCE issues this result code if DCE accepts this command.
ERROR:
The DCE issues this result code if <device> is not permitted.