Dell External OEMR R410 Owners Manual - Page 28
Check PSU and, Mismatch. PSU1
View all Dell External OEMR R410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E161C Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is attached to the system, but it has lost its AC input. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 151. E1620 Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's Check the AC power AC input is outside of the source for the specified allowable range. power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 151. E1624 Lost power supply redundancy. Check PSU cables. The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down. See "Troubleshooting Power Supplies" on page 151. E1626 Power Supply The power supplies in Mismatch. PSU1 the system are not the = ### W, PSU2 same wattage. = ### W. Ensure that power supplies with matching wattage are installed. See the Technical Specifications outlined in your system's Getting Started Guide. E1629 Power required > PSU wattage. Check PSU and config. The system configuration requires more power than the power supplies can provide, even with throttling. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. 28 About Your System