Dell External OEMR R410 Owners Manual - Page 31
SAS cable B, E2011 Memory
View all Dell External OEMR R410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E1A15 SAS cable B SAS cable B is missing failure. Check or bad. connection. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 167. E1A1D Control panel USB cable not detected. Check cable. USB cable to the control panel is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 167. E2010 Memory not detected. No memory was detected in the system. Inspect DIMMs. Install memory or reseat memory modules. See "Installing Memory Modules" on page 123 or "Troubleshooting System Memory" on page 152. E2011 Memory configuration failure. Check DIMMs. Memory detected, but is not configurable. Error detected during memory configuration. See "Troubleshooting System Memory" on page 152. E2012 Memory Memory configured, but is See "Troubleshooting configured but unusable. System Memory" on unusable. page 152. Check DIMMs. E2013 BIOS unable to The system BIOS failed to See "Troubleshooting shadow memory. copy its flash image into System Memory" on Check DIMMs. memory. page 152. E2014 CMOS RAM CMOS failure. CMOS failure. Power RAM not functioning cycle AC. properly. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 167. About Your System 31