Dell External OEMR R410 Owners Manual - Page 38
Table 1-3., System Messages, Message, Causes, Corrective Actions, ECC, DIMMs must
View all Dell External OEMR R410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 1-3. System Messages Message Causes Corrective Actions 128-bit Advanced ECC mode disabled. For 128-bit Advanced ECC, DIMMs must be installed in pairs. Pairs must be matched in size and geometry. The Advanced ECC option was enabled in BIOS, but is no longer valid due to an unsupported memory configuration, possibly a faulty or removed memory module. The Advanced ECC setting has been disabled. Check other messages for a faulty memory module. Reconfigure the memory modules for Advanced ECC mode. See "System Memory" on page 119. Alert! Advanced ECC Memory Mode disabled! Memory configuration does not support Advanced ECC Memory Mode. Advanced ECC Memory Mode was enabled in the system setup program, but the current configuration does not support Advanced ECC Memory Mode. A memory module may be faulty. Ensure that the memory modules are installed in a configuration that supports Advanced ECC Memory Mode. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 119. If the problem persists, see "Troubleshooting System Memory" on page 152. Alert! iDRAC6 not responding. Rebooting. The optional iDRAC6 is not responding to BIOS communication either because it is not functioning properly or has not completed initialization. The system will reboot. Wait for the system to reboot. 38 About Your System