Epson TM U200D Technical Reference - Page 133
Main Assembly 8 (Case Unit), Interface circuit board ass’y and Connector plate
View all Epson TM U200D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
TM-U200D/U200PD Technical Manual Main Assembly 8 (Case Unit) Interface circuit board ass'y and Connector plate 1. Turn over the printer. 2. Attach the Connector plate to the Interface circuit board ass'y and secure with the Hexagon lock screws (Serial interface) or the CPS-tite screws (parallel interface). 3. Connect the Interface circuit board ass'y to the Main circuit board ass'y and secure with the screws Serial Interface. CP(0) (M3x6) [0.59 to 0.78 N • m (6 to 8 kgf • cm)] Connector plate Hexagon lock screws [0.39 to 0.59 N • m (4 to 6 kgf • cm)] CP(0) (M3x6) [0.59 to 0.78 N • m (6 to 8 kgf • cm)] Interface circuit board ass'y Main circuit board ass'y Rev.B Disassembly, Assembly, and Adjustment 5-37
Rev.B
Disassembly, Assembly, and Adjustment
5-37
TM-U200D/U200PD Technical Manual
Main Assembly 8 (Case Unit)
Interface circuit board ass’y and Connector plate
1.
Turn over the printer.
2.
Attach the Connector plate to the Interface circuit board ass’y and secure with the Hexagon lock
screws (Serial interface) or the CPS-tite screws (parallel interface).
3.
Connect the Interface circuit board ass’y to the Main circuit board ass’y and secure with the screws
Serial Interface.
Hexagon
lock screws
[0.39 to 0.59 N • m
(4 to 6 kgf • cm)]
CP(0) (M3x6)
[0.59 to 0.78 N • m
(6 to 8 kgf • cm)]
CP(0) (M3x6)
[0.59 to 0.78 N • m
(6 to 8 kgf • cm)]
Connector plate
Interface circuit
board ass’y
Main circuit board ass’y