HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri
HP StorageWorks 1606 - Extension SAN Switch Manual
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 1606 manual content summary:
- HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 1
HP StorageWorks FOS 6.3.0b Release Notes Part number: 5697-0360 Second edition: March 2010 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 2
Legal and notice information © Copyright 2009-2010 Hewlett-Packard Development Company, L.P. © Copyright 2009-2010 Brocade Communications Systems, Incorporated - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 3
; 10-GbE ports require 10-GbE B-series SFPs.) • HP StorageWorks 1606 Extension SAN Switch, the next-generation distance extension platform for FCIP applications, supports 16 FC ports at 1, 2, 4, and 8 Gb/s, and 6 1-GbE optical ports. (The user can select either a copper or optical interface on two - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 4
and VMware ESX Server • Key vault credentials support for HP Secure Key Manager (SKM) • High availability (HA) clustered key vault support for HP SKM • FICON enhancements: Blade-based port swaps NOTE: For information about specific versions of FOS support for FICON, see the B-series FICON - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 5
over an IP network when the 1-GbE or 10-GbE ports are configured to support FCIP. FOS 6.3.0 and later supports up to 20 FCIP tunnels on a DC SAN Director Multiprotocol Extension Blade, and 8 FCIP tunnels on the 1606 Extension SAN Switch. The FCIP tunnels on the local and remote GbE ports act as the - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 6
interopmode 2 or 3 can now participate in M-EOS fabrics using nondefault DID Base Offset settings. NOTE: For specific information HP support for B-series and M-series interop fabrics, see the HP StorageWorks Merging Fabrics Based on M-series and B-series Fibre Channel Switches Application Notes. 6 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 7
that support the Access Gateway deployment. • Advanced Performance Monitoring-Enables performance monitoring of networked storage resources. This license includes the Top Talkers feature. • High-Performance Extension over FCIP/FC (formerly known as FC-IP Services)-For the HP StorageWorks B-series - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 8
platforms. • Integrated Routing license-Allows ports on a DC SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to be configured as EX_Ports, supporting FCR. This eliminates the need to add a Bseries Multiprotocol - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 9
VLAN Tagging • IEEE 802.1p, Class of Service Prioritization and Tagging • IEEE 802.1v, VLAN supported on the 2408 FCoE Converged Network Switch and DC SAN Director Switch 10/24 FCoE Blade: • IEEE 802.1Qbb, Priority-based Flow Control • IEEE 802.1Qaz, Enhanced Transmission Selection HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 10
SFPs, and 10-GbE ports require 10-GbE B-series SFPs. • 1606 Extension SAN Switch-Next-generation distance extension platform for FCIP applications. Supports 16 FC ports at 1, 2, 4, and 8 Gb/s, and 6 1-GbE optical ports. (The user can select either a copper or optical interface on two ports.) GbE - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 11
8-Gb SAN Switch for HP BladeSystem c-Class (Brocade 5480) • HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) • HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) • HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE10-24) • HP StorageWorks DC SAN Director - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 12
• HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director • HP StorageWorks 400 Multiprotocol Router • HP StorageWorks EVA4400 Embedded Switch Module • HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) Access Gateway was introduced with FOS 5.2.1b. It allows a switch to - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 13
products, see the HP website: http://www.hp.com IMPORTANT: The FOS versions listed in the Earliest compatible version column in Table 1 are the earliest versions supported by HP for connection to switches running FOS 6.3.0b at the time of the FOS 6.3.0b release. HP StorageWorks FOS 6.3.0b Release - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 14
support ended December 2007) N/A HP StorageWorks MSA SAN Switch 2/8 3.2.1c 3.2.1c1,6,7 HP StorageWorks Core Switch 2/64 HP StorageWorks SAN Director 2/128 in Chassis 5.0.5e Config modes 3 and 4 only 5.0.5f6,7 HP StorageWorks SAN Switch 2/8V HP StorageWorks SAN Switch 2/16V HP StorageWorks SAN - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 15
6.3.0b HP StorageWorks 8/8 SAN Switch HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 6.1.0f 6.3.0b5 HP StorageWorks Encryption SAN Switch 6.2.0b 6.3.0b HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.0 HP StorageWorks 2408 FCoE - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 16
and 2640 should not be used with XPath or FOS-based routing (FCR) for connections to the same edge fabric. 9 Using HP StorageWorks Fabric Manager (FM) 5.5 or earlier with FOS 6.1.1 or later can result in problems with Zoning, Performance monitoring, SYSLOG configuration, FICON wizards, IOD Delay - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 17
6.2.0b or later, with a maximum of four blades of this type on the DC SAN Backbone Director or DC04 SAN Director FX8-24 (DC SAN Director Multiprotocol Extension Blade) FCOE10-24 (DC SAN Director Switch 10/24 FCoE Blade) Supported with FOS 6.3.0x, with a maximum of two blades per director. The DC - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 18
is not supported in either the DC SAN Backbone Director or DC04 SAN Director with these blades. Fibre Channel Routing scalability For the latest information about Fibre Channel Routing (FCR) scalability support, see the HP StorageWorks SAN Design Reference Guide, available at: http://www.hp.com/go - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 19
in this release, that is, the earliest supported software versions that interoperate. HP recommends using the latest software versions to get the greatest benefit from the SAN. When using the new Virtual Fabrics (VF) feature, HP recommends that all switches participating in a fabric with a logical - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 20
-based products. All HP StorageWorks models supported by FOS 6.3.0x support both interopmodes 2 and 3, with the exception of the 4/32 SAN Switch, 2408 FCoE Converged Network Switch, and DC SAN Backbone Director or DC04 SAN Director with one or more DC SAN Director Switch 10/24 FCoE Blades. NOTE: HP - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 21
Path Selection (DPS, exchange-based routing) Dynamic Load Sharing (DLS, port-based routing) Virtual Channels ( Open E_Port6 Broadcast Zoning FDMI Remote Switch Port Mirroring Extended Fabrics Alias Server Platform Service FCIP (VE_Ports) IPFC (IP over Yes HP StorageWorks FOS 6.3.0b Release Notes 21 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 22
, M6140, and Mi10K. 2Allowed only between FOS-based switches. 3DPS is supported outbound from FOS-based switches. M-EOS can provide reciprocal load balancing using Open Trunking. 4SCC policies are supported only in conjunction with L2 Fabric Binding. 5Not supported in FOS 6.0 or later. 6Mode 3 is - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 23
and Encryption SAN Switch cannot be downgraded to a version earlier than FOS 6.2.0b. If there are multiple node encryption groups (EGs) in a fabric, complete the firmware download on one node at a time before downloading on another node. Firmware upgrade instructions IMPORTANT: HP recommends that - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 24
SAN Switch/DC SAN Director Multiprotocol Extension Blade and another 1606 Extension SAN Switch/DC SAN Director Multiprotocol Extension Blade. FCIP tunnels are not supported between the 1606 Extension SAN Switch/DC SAN Director Multiprotocol Extension Blade and the previous generation HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 25
: • On the 1606 Extension SAN Switch, the GigE port does not directly correlate to a VE_Port. • On the DC SAN Director Multiprotocol Extension Blade, GigE ports 0-9 or 10-GbE port 1 (xge1) correspond to VE_Ports 12-21, and 10-GbE port 0 (xge0) corresponds to VE_Ports 2231. HP StorageWorks FOS 6.3.0b - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 26
. Copper media is the default on GE0/GE1 ports and does not support autosense functions. • Inserting a 4 Gb SFP in GE ports of an HP StorageWorks 1606 Extension SAN Switch or DC SAN Director Multiprotocol Extension Blade, can occasionally return one of the following messages: • No_Light or Unknown - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 27
• To support nondisruptive firmware upgrades on the DC SAN Backbone Director/DC04 SAN Director, a new service, ethsw, is being introduced to enable Ethernet switching on the DC SAN Director Switch 10/24 FCoE Blade in FOS 6.3. LAN switching is disabled by default in FOS 6.3. The user must explicitly - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 28
in a fabric that uses these features. • VF is not supported on the 1606 Extension SAN switch. • VF-dedicated ISLs are supported on the DC SAN Director Switch Multiprotocol Extension Blade. XISLs are not supported. • On an HP StorageWorks 8/40 SAN switch with Virtual Fabrics enabled, ports may be re - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 29
user interfaces. • QoS is supported on switches in Access Gateway mode with FOS 6.3.0x. The fabric switches should be running FOS 6.3 to support QoS. If the fabric switch is FOS 6.2, QoS must be disabled on either switch Mi10K ports for the affected hosts. HP StorageWorks FOS 6.3.0b Release Notes 29 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 30
routing • To allow HCL on an 8/40 SAN Switch when using Integrated Routing, the edge switch connected to the 8/40 SAN Switch must be running FOS 6.1 or later. • Integrated Routing EX_Ports are supported only in the base switch on a switch with VF enabled. To test Integrated Routing functionality - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 31
Hot Code Load is not supported on the 8/40, 8/80, 400 MP Router, and 1606 SAN Extension switches. IFCCs may result if traffic is not stopped while downloading firmware. Firmware Downloads Replacement of a CP card in the 4/256 Director may cause disruption of I/O traffic. HP recommends that the CP - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 32
cable maintenance. Serviceability The 8Gb 48 port blade is supported as follows: • The switch, or logical switch, must be configured for Brocade Native mode (interopmode 0). • Only on VF-enabled chassis on the DC SAN Director. • Not supported in the default switch on the DC SAN Director. Traffic - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 33
port groups. • Port Mirroring is not supported on the 1606 Extension SAN Switch. 10G interoperability 10G interoperability between the HP StorageWorks SAN Director 6 Port 10Gb FC Blade and McDATA blades is not supported due to a hardware limitation. However, the SAN Director 6 Port 10Gb FC Blade is - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 34
support interoperability with these distance extension devices. FOS 6.3.0 and later allows Extended Fabrics E_Ports to operate in VC_RDY mode using either ARB or IDLE primitives as fill words. This allows frame-based trunking to be supported problems with the Idle/Idle sequence at 8 Gb. 8-Gb switches - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 35
VEX_Ports. Use the portCfgShow command to display user-configured fill-word settings. The execution of port to ARBFF-ARBFF: switch:admin> portcfgfillword 2/3, 1 See also the portCfgShow command in the Fabric OS Command Reference Manual. • Behavior: • HP StorageWorks FOS 6.3.0b Release Notes 35 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 36
manually changed to arb(ff) [mode 1], then they remain at arb(ff). Can be changed by the user. Mode: 0-IDLE for Link Init, IDLE for fill word 1-ARB(FF) for Link Init, ARB(FF) for fill word (NOTE: not supported with XP storage arrays) 16.1.2x was not supported on EVA4400 embedded switch module - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 37
SAN Backbone Director, DC04 SAN Director, or 4/256 SAN Director running FOS 6.3 in interopmode 2, the console log may generate continuous Unknown LSR type messages. You must either reboot the switch Fabric summary Monitor > Reports > Fabric Summary report HP StorageWorks FOS 6.3.0b Release Notes 37 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 38
Admin Admin Domain Switch Admin > DCC policies Performance Monitoring Configure > Zoning Comments Viewing FCIP tunnels is still supported in WebTools 6.1.1, report for both online and offline database Encryption behavior • HP recommends that the encrypted LUN containers be created when all - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 39
. If the user changes the LUN's settings during manual or auto, switches are not required in this case. • The disable EE interface CLI cryptocfg --disableEE [slot no] should be used only to disable encryption and security capabilities of the EE from the FOS Security Admin in the event HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 40
any CTCs. Ensure that all CTCs hosted on the HP Encryption Switch or HP Encryption Blade are either removed or moved to a errors will occur, such as key vault not responding and ultimately key archival and retrieval problems. • The HTTP server should be listening to port 9443. SKM is supported - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 41
Vaults. Two-way certificate exchange is supported. See the Encryption Admin Guide for configuration information. If you are using dual SKMs on Encryption SAN Switch/Encryption FC blade Encryption Group, these and the LUN can be used again for encryption. HP StorageWorks FOS 6.3.0b Release Notes 41 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 42
by default. To enable it, follow the procedure described in the SKM user guide, "Configuring the Key Manager for FIPS Compliance" section. NOTE: Per is required, HP strongly recommends that it be performed during the initial SKM configuration, before any key sharing between the switch and the SKM - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 43
disappear when rebooting the HP StorageWorks Encryption SAN Switch that has all the Target are no longer zoned together, then the user should also remove the associated container (i.e., frame display the switch. Applications that write to a LUN that is being rekeyed may see I/O errors. Fixed - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 44
the issue. NPIV devices in Interopmode 2 default zone is not supported. NPIV devices should be part of the active zone configuration. Fabric switch disable. HA cluster member node, HP StorageWorks Encryption SAN Switch faults as a result of slot powercycling its HA cluster peer (HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 45
user password is NOT generated as seen from the console log, thereby causing a NO COMM on the VCM. Fixed in FOS 6.3.0 Workaround prior to code change: Power off and Power on the Switch via OA should fix the problem. Swapping HP StorageWorks 32 port 8Gb FC blade with 48 port blade in DC04 SAN - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 46
change: Add an ISL on the user port lower than the lowest Fport on switch. Multiple repetitions of port enable/disable might result in a lost route Fixed in FOS 6.3.0 in an HP StorageWorks 4/256 SAN Director configuration. "NO Comm" observed when remove HP VC switch from Bay 3 and installed in Bay - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 47
tape pipelining active, the switch may return a good status without Fixed in FOS 6.3.0 sending data. DC SAN Director ASIC parity errors, ICL CRC's and IFCC's on overnight workload. Fixed in FOS 6.3.0 Host detecting IFCCs errors to CUP Port. Fixed in FOS 6.3.0 HP StorageWorks FOS 6.3.0b Release - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 48
Encryption Fixed in FOS 6.3.0 SAN Switch. Node descriptors are missing for DC SAN Director and DC04 SAN Fixed in FOS 6.3.0 Director with Fibrechannel Fastwrite (FCFW) enabled has problems with Fixed in FOS 6.3.0 port disable/enable of HBA ports. Switch Kernel panics when performing VMware VMotion ( - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 49
database. After rebooting one Encryption SAN Switch of a HAC that has connectivity error: ERROR, SYS, Crypto tape receives service failure in tape_cmd_pre_execution_scsi_chk: PI BLK size > RBL, 0x0, Fixed in FOS 6.3.0 tape_util.c, line: 5002. User switch. HP StorageWorks FOS 6.3.0b Release Notes 49 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 50
problem switches. Data Miscompare after Encryption SAN Switch power cycle. Fixed in FOS 6.3.0 Out of Memory due to switch not timing out in.telnetd processes. Fixed in FOS 6.3.0 Workaround prior to code change: Reboot the switch. Transmitted Rate / Received rates based . RTWR error when going - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 51
SAN Switch for HP c-Class BladeSystem AG may login to DC SAN Director with wrong pwwn. Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 Workaround prior to code change: Reboot AG. OpenVMS init command is not correctly supported FOS 6.3.0 and 8/8 or 8/16 switches. HP StorageWorks FOS 6.3.0b Release Notes 51 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 52
errors when . Need to support a command " user to provide valid input. High Availability : User is able to change the "desired distance" for long distance "L0".User SAN Director and Multiprotocol Router Blade EX port stuck without showing switch name of the edge fabric switch etc during edge switch - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 53
switch authentication failure may be seen. Workaround prior to code change: Issue hafailover or hareboot. Add FIP version 0 handling. Fixed in FOS 6.3.0 Address configdownload problems on 4Gb SAN switch for HP c-Class Confusing error message when HP StorageWorks FOS 6.3.0b Release Notes 53 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 54
EoS switches. Fixed in FOS 6.3.0 Blades are not shown in when a slot is hot plugged in to a DC SAN Fixed in FOS 6.3.0 Director or DC04 SAN Director. With VF, deleting a FID while in the FID leads to undesirable conditions. The user is stuck in the FID and all commands run generate an error Fixed - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 55
middle 2 bytes, since the error message says the last 2 must be 0x00. Fixed in FOS 6.3.0 Switches bouncing between reachable/unreachable in edge FCoE CN Switch. Fixed in FOS 6.3.0 8/8 or 8/16 SAN Switch not responding to Link Reset primitives cor- Fixed in FOS 6.3.0 rectly. HP StorageWorks FOS - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 56
SAN Switch for HP BladeSystem c- Fixed in FOS 6.3.0 Class. Blade fault observed with a 4/256 SAN SAN Switch and Encryption FC blade do not support en- Fixed in FOS 6.3.0 crypted LUNs >2TB. Switch Admin: Proper error do a manual reboot. 2. Need to power cycle the switch. The switch functions properly - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 57
community configuration. 8/80 SAN Switch: Removing any power Error message is shown when launching SCSI Read/Write on a LUN Per port graph. Fixed in FOS 6.3.0 Enabled minimum FOS support for DWDM-SFP port media. Fixed in FOS 6.3.0 Re-keys are getting stuck. Fixed in FOS 6.3.0 HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 58
DC SAN Director: configdownload: simple upload/download (switch enabled) complaining about FID 128 and will not download with Fixed in FOS 6.3.0 switch enabled. Switch Admin: CEE: NPE is shown in error message when user applies a new FCoE login group (with Login management disabled.) Fixed in - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 59
Fabric (VF) through DCFM on 8/40 SAN Switch. Fixed in FOS 6.3.0 Fabric watch: (java.lang.illegalArgumentException:Invalid logid) error message box will appear when selecting Configuration ." The lfcfg command shows incorrect data. Fixed in FOS 6.3.0 HP StorageWorks FOS 6.3.0b Release Notes 59 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 60
attributes. Can clean up problem by using zone --add to modify the attributes again after the save. Can also delete and recreate TI zone. Specific call to CEE library results in gradual memory leak. Fixed in FOS 6.3.0 Getting ms_ficon errors on console of core DC SAN Director in McDATA interop - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 61
SAN Director with 8 logical switches services while performing stress testing. FOS-FVT- If a Read is Sent Busy Status and the Subsequent Seek is also Fixed in FOS 6.3.0 Sent Busy, Mis-Compares To the Host. Downloading config file between switches the user HP StorageWorks FOS 6.3.0b Release Notes 61 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 62
Fixed in FOS 6.3.0 Appropriate message is not shown in the message box, when the "Details" button in the "Service" tab of "HA" window is clicked. Fixed in FOS 6.3.0 High Availability: The error message thrown is not relevant or meaningful, when the values for E_D_TOV and R_D_TOV in the "Configure - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 63
Switch. Fixed in FOS 6.3.0 Unexpected software call traceback error messages are being displayed on the console. Fixed in FOS 6.3.0 DC SAN type that does not support auto mode. Fixed in user the ports will be disabled. Fixed in FOS 6.3.0 If switches HP StorageWorks FOS 6.3.0b Release Notes 63 - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 64
After user configured key ID without commit, CAL doesn't return key ID value. Auditcfg does not generate RBAC permission denied messages. Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 4Gb SAN Switch for c-Class BladeSystem puts out frequent warning messsages (HIL-1505) that the temperature is above the - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 65
firmwaredownload and reboot of DC SAN Director. Fixed in FOS for SSH outgoing authentication from the switch or: The workaround was to users will notice a message on standby CP console: "cannot Fixed in FOS 6.3.0 create symbolic link '/etc/localtime' to '/usr/share/zoneinfo/..." HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 66
Flash" Console Message is seen on all FOS Switches in Fabric during Configupload on Single FOS Switch in a Interopmode 2 fabric. Fixed in FOS 6.3.0 Block user from configuring QoS on 6-port 10Gb ISL blade. Fixed in FOS 6.3.0 Inappropriate error message from configuredownload in VF mode and LSAN - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 67
user mode" and termination of ficud. SR Request for IBM PMH 85437,000,738 - HK Monetary. Fixed in FOS 6.3.0 Unable to clear Port Name from screen " Edit CUP Port Connectivity Configuration." SNMP changes required to better support snmp mib. Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 HP StorageWorks - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 68
services. Fixed in FOS 6.3.0 Workaround prior to code change: Issue an additional reboot or hafailover. Fabstateshow log wrapping overwrites useful fabstate data on the switch when interoperating with McDATA switches Fixed in FOS 6.3.0 owner) switch is still disabled. Error message may be seen on - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 69
on HP StorageWorks DC SAN Director Multiprotocol Extension Blade running HP StorageWorks 1606 Extension Switch or Multiprotocol Extension Blade. Fixed in FOS 6.3.0a Zoning fails with Transaction Commit failed. Reason code 2 (26) - Aca was rejected: Remote Switch Busy, Retry in a few seconds error - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 70
0s 0.00 0.00 0 0/0 0). With 1606 Extension SAN Switch or Multiprotocol Extension Blade, FCIP configuration cannot be restored to default setting by using configdefault, even after chassis reboot. Fixed in FOS 6.3.0a HP StorageWorks Encryption SAN Switch or encryption blade drops frames received - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 71
on HP StorageWorks Extension SAN Switch or Multiprotocol Extension Blade will continually showail No_Sync status if non-B-series SFP was inserted and then replaced with B-series SFP. Fixed in FOS 6.3.0a Workaround prior to code change: Use portdisable and portenable after inserting the supported - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 72
in the fabric (HP StorageWorks 1606 Extension SAN Switch and Multiprotocol Extension Blade). This can lead to other important RASLOG messages being lost. This condition occurs with IPSEC, which is not supported in this release. Fixed in FOS 6.3.0b HP StorageWorks DC SAN Director panicks and - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 73
a FICON environment, a kernel panic causes the Fixed in FOS 6.3.0b switch to crash and reboot. An HP Storageworks 1606 SAN Extension Switch crashes after connecting FCIP ports to a test device that performs various perturbations/error injection on the port. Fixed in FOS 6.3.0b A strict fabric - HP StorageWorks 1606 | HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 74
74
HP StorageWorks FOS 6.3.0b Release
Notes
Part number: 5697-0360
Second edition: March 2010