HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 56
WebTools Zone Admin
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
When a trunk master port is disabled, fabric watch incorrectly sets the new trunk master's health to offline, and remote side to faulty even though port is online. Fixed in FOS 6.3.0 Workaround prior to code change: New master incorrectly reported as offline or faulty after trunk master disable. No workaround, hafailover can be used as recovery. CAL Response for Brocade_ISL CAL class is returning wrong port information in case of Edge to Backbone Device Sharing (when TD is available in FCR fabric). Fixed in FOS 6.3.0 Console is not accessible on 8GB SAN Switch for HP BladeSystem c- Fixed in FOS 6.3.0 Class. Blade fault observed with a 4/256 SAN Director chassis fully loaded Fixed in FOS 6.3.0 with 8Gb 48-port blades. Deleted offline/inactive device using zone validate window in EZman- Fixed in FOS 6.3.0 ager is not replicated in CLI. Encryption SAN Switch and Encryption FC blade do not support en- Fixed in FOS 6.3.0 crypted LUNs >2TB. Switch Admin: Proper error message should pop up when disabling of FCoE in a VLAN fails. Fixed in FOS 6.3.0 Workaround prior to code change: View the switch events to determine the reason for failure. Switch panic when supportsave read invalid data on GE ports without Fixed in FOS 6.3.0 FC Fastwrite enabled. Firmware downgrade from FOS v6.2.0 to v6.1.0 sometimes causes an unresponsive console, which requires a switch power cycle to recover. Fixed in FOS 6.3.0 Workaround prior to code change: 1. Avoid using firmwaredownload -sb i.e. avoid auto-reboot. Use firmwaredownload -s and then do a manual reboot. 2. Need to power cycle the switch. The switch functions properly after power cycle with normal access to the telnet session. Rekeyed LUNs are in "Not Ready (Getting key from archive)" state when the key vault goes down and does not recover. WebTools Zone Admin "Add member" button is always disabled. Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 Workaround prior to code change: Add members with the "Add other" button. In non-VF mode on DC SAN Director, after removing other filters (EE and F_Port TT) and enabling Fabric mode TopTalkers, the flow values are not reliable. Fixed in FOS 6.3.0 HA Failover on DC SAN Director caused: Need to reboot the system for recovery, reason: System bring up timed out. Fixed in FOS 6.3.0 Workaround prior to code change: Mannually block and unblock an E_Port to rebuild the fabric. 56