HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 58
Close and re-open Fabric Watch
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
DC SAN Director: configdownload: simple upload/download (switch enabled) complaining about FID 128 and will not download with Fixed in FOS 6.3.0 switch enabled. Switch Admin: CEE: NPE is shown in error message when user applies a new FCoE login group (with Login management disabled.) Fixed in FOS 6.3.0 Workaround prior to code change: User has to execute the CLI command fcoelogincfg before using WebTools to create the login groups. pertperfshow does not display decimal data if overall throughput ex- Fixed in FOS 6.3.0 ceeds 10Gbps. A switch restart causes random ICL E-Ports to come up "segmented." Fixed in FOS 6.3.0 Workaround prior to code change: Port toggle when it gets segmented. When running FCoE traffic, debug_csock_read_header failures mes- Fixed in FOS 6.3.0 sage displays. Fabric Watch: The FRU status does not auto-refresh after removal/insertion of the FRU. Fixed in FOS 6.3.0 Workaround prior to code change: Close and re-open Fabric Watch. FCoE frames from any SMAC are incorrectly passed to the FC side. Fixed in FOS 6.3.0 Switchname mismatch between GUI display and CLI. Fixed in FOS 6.3.0 Issues with Brocade MIB objects with ifSpeed returns wrong value, ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards, Fixed in FOS 6.3.0 snmpSilentDrops, snmpProxyDrops needs to be documented. After cfgdefault and migration from Interopmode 0 to Interopmode 2, all switches are setting idid bit in ESA, when idid is not enabled. Fixed in FOS 6.3.0 Workaround prior to code change: Fabric can be merged by disabling the switches and setting idid mode in the switch configurations, then bringing the switches online. This option is applicable only in the event the user wishes to merge the switch to a fabric that also has idid set. Syshutdown: execution of command in current build yields only "this Fixed in FOS 6.3.0 is a unknown system" string on session consoles. Cannot use "fwconfigure" to view the information on internal F/FL ports (Copper). Fixed in FOS 6.3.0 Internal routes are not being configured. Fixed in FOS 6.3.0 Port state mismatch on internal copper ports on Embedded platforms Fixed in FOS 6.3.0 between switchshow and portcfgshow's PersistentDisable flag. The Distribute Policy option is missing from the SCC and DCC tabs in Fixed in FOS 6.3.0 web mgmt. Supportshow cli command output should complete without having to Fixed in FOS 6.3.0 hit CR several times. 58