HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 71
FOS 6.3.0b fixes, lists defects closed in the FOS 6.3.0b firmware release.
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
ifName value returned for xGBE port in WebTools does not match CLI output. Fixed in FOS 6.3.0a If the ITL nexus in tape (target containers with initiator) to handle multiplex/multistream environment is greater than 200, decreased performance is seen for some containers. Fixed in FOS 6.3.0a Workaround prior to code change: Reduce IT configurations (target containers with initiators) to 200. NPIV tape devices may not be seen by hosts due to name server not sending subsequent PLOGI ACC following a sequence where NPIV device sends LOGO before link down. Fixed in FOS 6.3.0a GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol Extension Blade will continually showail No_Sync status if non-B-series SFP was inserted and then replaced with B-series SFP. Fixed in FOS 6.3.0a Workaround prior to code change: Use portdisable and portenable after inserting the supported SFP. Copper 1-GbE SFP can get into an illegal state on Extension SAN Switch where no LED light is shown, but port is online and working. Fixed in FOS 6.3.0a FOS 6.3.0b fixes Table 12 lists defects closed in the FOS 6.3.0b firmware release. Table 12 FOS 6.3.0b closed defects Closed defect summary Solution When an unsupported SFP is installed in an HP StorageWorks DC SAN Director Multiprotocol Extension Blade, the amber LED flashes to indicate a fault, as it should. However, if an optical cable is plugged into the SFP, the amber LED extinguishes. The actual port status is unchanged. Fixed in FOS 6.3.0b When Lossless DLS is enabled, WebTools incorrectly shows iodset off, but the CLI shows that it is enabled. Fixed in FOS 6.3.0b Workaround prior to upgrade: Use the CLI to view the configured IOD state when IOD is enabled with the Lossless DLS solution. In a rare case, a buffer leak in the rekey daemon causes an HP StorageWorks Encryption SAN Switch fault during rekey. A power cycle is required to recover. Fixed in FOS 6.3.0b HP StorageWorks Encryption SAN Switch does not rejoin Encryption Fixed in FOS 6.3.0b Group after a reboot, resulting in a split Encryption Group. Incorrect port shows I/O traffic on 2408 FCoE Switches and 10/24 Fixed in FOS 6.3.0b FCoE Blades. When launched from DCFM, WebTools fails with a license error. Fixed in FOS 6.3.0b The host cannot recover if a back-end tape target becomes unrespons- Fixed in FOS 6.3.0b ive during encryption switch-initiated commands. HP StorageWorks FOS 6.3.0b Release Notes 71