HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 52

On some of 2408 FCoE Converged Network switches, DIAGPOST is

Page 52 highlights

FICON XRC Emulation error handling OOO Status Frames. Fixed in FOS 6.3.0 Workaround prior to code change: Option 1: Deactivate all paths that utilize the same device ports and reactivate at the same time. Option 2: Disable FICON XRC emulation. HIL-1610 WARNING appeared on 8/40 switch units after power cycle. Fixed in FOS 6.3.0 Workaround prior to code change: Ignore the warning - it is innocuous when seen right at boot up time. It results from a solitary spurious sensor reading that is below minimum. Temperature sensor reporting spurious solitary readings which leads to the CRITICAL HIL-1502 message, without having first gone through the HIL-1501 warning. Fixed in FOS 6.3.0 Workaround prior to code change: Ignore isolated / spurious High Temperature CRITICAL errors when not preceeded by warnings. Unable to get F Ports(Trunk Ports) data. Fixed in FOS 6.3.0 On some of 2408 FCoE Converged Network switches, DIAGPOST is Fixed in FOS 6.3.0 failing due to loss of sync. Processor rebooted - Software Fault:ASSERT when frame size received Fixed in FOS 6.3.0 is too big. Need to support a command "clear logging" to clear all debug log messages accumulated. Fixed in FOS 6.3.0 Workaround prior to code change: Go to FOS mode and issue an "errclear" command. CLI output consistency and input validation issues around key lifespan option of a LUN. Fixed in FOS 6.3.0 Workaround prior to code change: Input validation issues. Requires the user to provide valid input. High Availability : User is able to change the "desired distance" for long distance "L0".User should not be able to change the "Desired distance", if the "Long distance" value is "L0". It should always be "N/A" for L0. Fixed in FOS 6.3.0 After firmware upgrade, FC FastWrite traffic sometimes fails. Fixed in FOS 6.3.0 A few VERIFY are dump out on DC SAN Director and Multiprotocol Router Blade EX port stuck without showing switch name of the edge fabric switch etc during edge switch firmwareupgrade. Fixed in FOS 6.3.0 FMS mode should be blocked when a logical switch is in 10 bit ad- Fixed in FOS 6.3.0 dressing. TI Zone activation failed when pushing from DCFM to fabric with v6.2.0 and v6.1.2. Fixed in FOS 6.3.0 The drive is taken offline after container is failed back. Fixed in FOS 6.3.0 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Fixed in FOS 6.3.0
Workaround prior to code change:
Option 1: Deactivate all paths that
utilize the same device ports and
reactivate at the same time. Option
2: Disable FICON XRC emulation.
FICON XRC Emulation error handling OOO Status Frames.
Fixed in FOS 6.3.0
Workaround prior to code change:
Ignore the warning - it is innocuous
when seen right at boot up time. It
results from a solitary spurious sensor
reading that is below minimum.
HIL-1610 WARNING appeared on 8/40 switch units after power
cycle.
Fixed in FOS 6.3.0
Workaround prior to code change:
Ignore isolated / spurious High
Temperature CRITICAL errors when
not preceeded by warnings.
Temperature sensor reporting spurious solitary readings which leads
to the CRITICAL HIL-1502 message, without having first gone through
the HIL-1501 warning.
Fixed in FOS 6.3.0
Unable to get F Ports(Trunk Ports) data.
Fixed in FOS 6.3.0
On some of 2408 FCoE Converged Network switches, DIAGPOST is
failing due to loss of sync.
Fixed in FOS 6.3.0
Processor rebooted - Software Fault:ASSERT when frame size received
is too big.
Fixed in FOS 6.3.0
Workaround prior to code change:
Go to FOS mode and issue an
"errclear" command.
Need to support a command "clear logging" to clear all debug log
messages accumulated.
Fixed in FOS 6.3.0
Workaround prior to code change:
Input validation issues. Requires the
user to provide valid input.
CLI output consistency and input validation issues around key lifespan
option of a LUN.
Fixed in FOS 6.3.0
High Availability : User is able to change the "desired distance" for
long distance "L0".User should not be able to change the "Desired
distance", if the "Long distance" value is "L0". It should always be
"N/A" for L0.
Fixed in FOS 6.3.0
After firmware upgrade, FC FastWrite traffic sometimes fails.
Fixed in FOS 6.3.0
A few VERIFY are dump out on DC SAN Director and Multiprotocol
Router Blade EX port stuck without showing switch name of the edge
fabric switch etc during edge switch firmwareupgrade.
Fixed in FOS 6.3.0
FMS mode should be blocked when a logical switch is in 10 bit ad-
dressing.
Fixed in FOS 6.3.0
TI Zone activation failed when pushing from DCFM to fabric with
v6.2.0 and v6.1.2.
Fixed in FOS 6.3.0
The drive is taken offline after container is failed back.
52