HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 27
For HP StorageWorks DC SAN or DC04 SAN Directors with one or more SAN Director Switch
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
• HP recommends that Spanning Tree Protocol and its variants be disabled on CEE interfaces that are connected to a server. • The Fabric Provided MAC Address (FPMA) and Fibre Channel Identifier (FCID) assigned to a VN_Port cannot be associated with any front-end CEE port on which the FLOGI was received. • LLDP neighbor information may be released before the timer expires when DCBX is enabled on a CEE interface. This occurs only when the CEE interface state changes from active to any other state. When the DCBX is not enabled, the neighbor information is not released until the timer expires, regardless of the interface state. • The FCoE login group name should be unique in a fabric-wide FCoE Login Management Configuration. The merge logic is designed to modify the login group name during merge when login group names in participating configurations conflict with each other. The current Organizationally Unique Identifier (OUI) of 00051E is being used by Brocade while assigning the WWNs to 2408 FCoE Converged Network Switches, DC SAN Backbone Directors, and DC04 SAN Directors, which would make only the last three bytes different for any two 2408 FCoE Converged Network Switches, DC SAN Backbone Directors, or DC04 SAN Directors. Considering this assignment method, the merge logic would rename the login group by including the last three bytes of the WWN in the login group name, so that they are unique in the merged configuration. • For switches having different OUI indexes from the eight assigned to Brocade (for example, 00051E and 006069), WWNs can differ in more than three bytes. In this case, after a normal merge and a rename, per the logic described above, login group names can be the same for WWNs differing only in OUIs. The merge logic would drop one of the login groups to satisfy the requirement to keep the login group name unique in the fabric-wide configuration. • Ethernet switch services must be explicitly enabled using the command fosconfig -enable ethsw before powering on a DC SAN Director Switch 10/24 FCoE Blade. Failure to do so causes the blade to be faulted (fault 9). • To support nondisruptive firmware upgrades on the DC SAN Backbone Director/DC04 SAN Director, a new service, ethsw, is being introduced to enable Ethernet switching on the DC SAN Director Switch 10/24 FCoE Blade in FOS 6.3. LAN switching is disabled by default in FOS 6.3. The user must explicitly enable Ethernet switch service using the command fosconfig -enable ethsw to prevent FC traffic interruption. • Upgrading from FOS 6.x to 6.3 is nondisruptive. You can enable ethsw after upgrading without interrupting FC traffic. Upgrading the 2408 FCoE Converged Network Switch from FOS 6.1.2_cee1 to 6.3 will disrupt the FC traffic. • For HP StorageWorks DC SAN or DC04 SAN Directors with one or more SAN Director Switch 10/24 FCoE blades installed, downgrading or upgrading the FOS 6.3 firmware to another version disrupts traffic through the blades. HA Failover of CP blades in either of these directors disrupts traffic through the 10/24 FCoE blades. • Upgrades from FOS 6.3 to future releases will be nondisruptive to data traffic and will have behavior similar to a CP failover; ethsw remains unchanged. • Downgrade from FOS 6.3 to 6.1.2_cee1 is disruptive if ethsw is enabled on FOS 6.3. • Downgrade from FOS 6.3 to 6.1.2_cee1 is nondisruptive if ethsw has never been enabled with FOS 6.3. • Connecting a 2408 FCoE Converged Network Switch to an FCR-capable switch with fcrbcast config enabled will cause a storm of broadcast traffic, resulting in termination of iswitchd. HP StorageWorks FOS 6.3.0b Release Notes 27