HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 61
FOS-FVT- If a Read is Sent Busy Status and the Subsequent Seek is also
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
If TI zone operations are performed simultaneously on different switches, active CP may failover due to termination of Name server module. Fixed in FOS 6.3.0 Workaround prior to code change: No workaround needed, the DC SAN Director CP fails over non-disruptively and retains all configuration data. 4Gb switch running at fixed 2Gb speed may not respond to FLOGI from HBA using auto-speed negotiation. Fixed in FOS 6.3.0 Workaround prior to code change: Lock the port to fixed speed. Detected termination of management server daemon during stress testing on DC SAN Director with 8 logical switches. Fixed in FOS 6.3.0 Workaround prior to code change: Wait for system to stabilize after executing bladedisable and before issuing hafailover or disable MS platform services while performing stress testing. FOS-FVT- If a Read is Sent Busy Status and the Subsequent Seek is also Fixed in FOS 6.3.0 Sent Busy, Mis-Compares To the Host. Downloading config file between switches causes license lost. Fixed in FOS 6.3.0 Workaround prior to code change: Do the following to back up licenses: 1. Execute licenseshow command save the licenses into a file outside the switch. 2. Then perform configdownload. 3. Add the licenses saved in step one. Inconsistent display of urouteshow trying to map to invalid FCR user port while topologyshow is not showing those routes. Fixed in FOS 6.3.0 If user account on RADIUS server is set up with only Chassis level role as primary, but it is not on the LF role list, the user cannot login. Fixed in FOS 6.3.0 Workaround prior to code change: Specify LF role list in the RADIUS server for the account. Missing Pause and Resume for EX port having MiI10K Edge Fabric in Fixed in FOS 6.3.0 239 Domain - works for domain 209-238. While performing security related fabric wide operations if fabric becomes unstable, user might observe verify on standby. Fixed in FOS 6.3.0 Workaround prior to code change: System will recover. Setting the E-Net portname on the Primary CP does not get copied over to the standby CP. Fixed in FOS 6.3.0 NPIV devices on a single port are spread across effective and McDATA default configurations, only devices from default configuration can establish communication. Fixed in FOS 6.3.0 Workaround prior to code change: Do not overlap effective and default zones on the same NPIV port, following best practices guidelines. Access Gateways connected to EOSc in a mixed fabric (FOS and EOS) are not shown in DCFM. Fixed in FOS 6.3.0 HP StorageWorks FOS 6.3.0b Release Notes 61