HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 47
DC SAN Director ASIC parity errors, ICL CRC's and IFCC's
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Pending Merge: Repeatedly disconnect/reconnecting the ISL links between the HP StorageWorks Encryption SAN Switch in the HA cluster environment while rekey operations are in progress may cause data miscompare. Fixed in FOS 6.3.0 Encryption group can't automatically recover after it is split into 2 dif- Fixed in FOS 6.3.0 ferent islands. Firmwaredownload failed on HP StorageWorks DC SAN Director. Fixed in FOS 6.3.0 Pending Merge: Host throughput drops 75% when rekey is started. Fixed in FOS 6.3.0 All LUNs in a container are showing target offline. Fixed in FOS 6.3.0 After encountering a rare error condition, a switch/director may fail Fixed in FOS 6.3.0 to clear an interrupt, resulting in a persistently high CPU load. SNMP v3 user configuration reverts back to defaults after HAfailover. Fixed in FOS 6.3.0 IFCC's when disabling trunks and having DPS enabled. Fixed in FOS 6.3.0 Reset factory default using the faceplate pinhole caused FFDC and VCM shows "No Communication" to the switch Fixed in FOS 6.3.0 Pending Megre: During rekey operations, continuously disconnect/reconnect the ISL links between 2 cluster nodes, causes one of the LUN Fixed in FOS 6.3.0 to hang at "LUN discovery" state. Pending merge: Rekeying and toggling ISL to trigger HAC failover in 4 node dual fabric caused the DC Switch Encryption Blade in slot3 of the DC SAN Director and Encryption SAN Switch fault: BKSW-1003] HL_BES101, kSWD: Detected unexpected termination of: ''[4]CVLC. Fixed in FOS 6.3.0 DC SAN Director-upgrade from v6.1.1a to v6.2.0, hit FFDC, then panic-detected termination of process pdmd:2676. Fixed in FOS 6.3.0 Workaround prior to code change: CPs were not in sync when downgrading to v6.1.1a. Did net install on DC SAN Director to v6.1.1a and upgrade to v6.2.0b. Pending Merge: Encryption SAN Switch Faulty during reboot -f test. Fixed in FOS 6.3.0 SNMPd core file filled up the root file system on the DC04 SAN Direct- Fixed in FOS 6.3.0 or. Continuously disconnect/reconnecting the ISLs in the HA environment Fixed in FOS 6.3.0 causes one of the Encryption SAN Switches to go into faulty state. Command "fddcfg -fabwideset" and other security commands fails with RCS transaction error. Fixed in FOS 6.3.0 With tape pipelining active, the switch may return a good status without Fixed in FOS 6.3.0 sending data. DC SAN Director ASIC parity errors, ICL CRC's and IFCC's on overnight workload. Fixed in FOS 6.3.0 Host detecting IFCCs errors to CUP Port. Fixed in FOS 6.3.0 HP StorageWorks FOS 6.3.0b Release Notes 47