HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 54

Director or DC04 SAN Director., Fixed in FOS 6.3.0

Page 54 highlights

WebTools Switch Admin: QoS: User defined priority group 0-7 does not show up in the drop down for priority group id. Fixed in FOS 6.3.0 Workaround prior to code change: Use CLI to map user defined priority group to a CoS. 8/8 or 8/16 returned invalid value for 'swFCPortFlag' MIB object from 8/8 or 8/16 on SNMP manager. Fixed in FOS 6.3.0 MAC learning/flushing times are very slow on 2408 FCoE CN Switch Fixed in FOS 6.3.0 Switch. Switch crashed on sending LOGO from Finisar LT. Fixed in FOS 6.3.0 Virtual Fabrics 6.2.0c when XISL use is enabled base logical switch in switchshow shows Allow XISL Use as "off" open RFE 1249. Modify fipcfg --advintvl cli to reject non-zero values for FKA interval. Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 CUP needs to send an RSCN after coming back online after a cold boot. Fixed in FOS 6.3.0 WT: FCoE connected devices tab, sort order of Device WWN is incor- Fixed in FOS 6.3.0 rect. In an FCR environment, switch runs out of memory when connected with EoS switches. Fixed in FOS 6.3.0 Blades are not shown in when a slot is hot plugged in to a DC SAN Fixed in FOS 6.3.0 Director or DC04 SAN Director. With VF, deleting a FID while in the FID leads to undesirable conditions. The user is stuck in the FID and all commands run generate an error Fixed in FOS 6.3.0 message. FOS still reports some FRU failures as link incidents on port 0xFF. Fixed in FOS 6.3.0 After FCoE login, FOS v6.1.2_cee does not filter packets with SRCMAC=FCF-MAC. Fixed in FOS 6.3.0 Reboot of all 4 nodes in an Encryption Group (EG) with multiple rekeys Fixed in FOS 6.3.0 pending resulted in new rekey sessions being unable to start. IPFC address is shown instead of chasis IP address in SNMP Trap for Fixed in FOS 6.3.0 DC04 SAN Director. Required detailed error description while the port enable/disable fails. Fixed in FOS 6.3.0 Man page/online help on "fcoelogingroup --create xxx" should replace Fixed in FOS 6.3.0 allow-all by "allowall." Pathinfo command failure occurs when run on FOS 6.1, if the path traverses through FOS 6.2.x. Fixed in FOS 6.3.0 2408 FCoE CN Switch should be able to set enable password. Fixed in FOS 6.3.0 When Quality of Service (QoS) is enabled by default / not utilized, performance of the SAN drops. Disable QoS by default on 4Gb platforms, 8Gb long-distance and make portcfg values such as fill words, trunk information persistent across upgrade/downgrades. Fixed in FOS 6.3.0 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Fixed in FOS 6.3.0
Workaround prior to code change:
Use CLI to map user defined priority
group to a CoS.
WebTools Switch Admin: QoS: User defined priority group 0-7 does
not show up in the drop down for priority group id.
Fixed in FOS 6.3.0
8/8 or 8/16 returned invalid value for 'swFCPortFlag' MIB object
from 8/8 or 8/16 on SNMP manager.
Fixed in FOS 6.3.0
MAC learning/flushing times are very slow on 2408 FCoE CN Switch
Switch.
Fixed in FOS 6.3.0
Switch crashed on sending LOGO from Finisar LT.
Fixed in FOS 6.3.0
Virtual Fabrics 6.2.0c when XISL use is enabled base logical switch
in switchshow shows Allow XISL Use as "off" open RFE 1249.
Fixed in FOS 6.3.0
Modify fipcfg --advintvl cli to reject non-zero values for FKA interval.
Fixed in FOS 6.3.0
CUP needs to send an RSCN after coming back online after a cold
boot.
Fixed in FOS 6.3.0
WT: FCoE connected devices tab, sort order of Device WWN is incor-
rect.
Fixed in FOS 6.3.0
In an FCR environment, switch runs out of memory when connected
with EoS switches.
Fixed in FOS 6.3.0
Blades are not shown in when a slot is hot plugged in to a DC SAN
Director or DC04 SAN Director.
Fixed in FOS 6.3.0
With VF, deleting a FID while in the FID leads to undesirable conditions.
The user is stuck in the FID and all commands run generate an error
message.
Fixed in FOS 6.3.0
FOS still reports some FRU failures as link incidents on port 0xFF.
Fixed in FOS 6.3.0
After FCoE login, FOS v6.1.2_cee does not filter packets with SRC-
MAC=FCF-MAC.
Fixed in FOS 6.3.0
Reboot of all 4 nodes in an Encryption Group (EG) with multiple rekeys
pending resulted in new rekey sessions being unable to start.
Fixed in FOS 6.3.0
IPFC address is shown instead of chasis IP address in SNMP Trap for
DC04 SAN Director.
Fixed in FOS 6.3.0
Required detailed error description while the port enable/disable fails.
Fixed in FOS 6.3.0
Man page/online help on "fcoelogingroup --create xxx" should replace
allow-all by "allowall."
Fixed in FOS 6.3.0
Pathinfo command failure occurs when run on FOS 6.1, if the path
traverses through FOS 6.2.x.
Fixed in FOS 6.3.0
2408 FCoE CN Switch should be able to set enable password.
Fixed in FOS 6.3.0
When Quality of Service (QoS) is enabled by default / not utilized,
performance of the SAN drops. Disable QoS by default on 4Gb plat-
forms, 8Gb long-distance and make portcfg values such as fill words,
trunk information persistent across upgrade/downgrades.
54