HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 62
FICON FCIP Acceleration error - FCCU LinkBusy from non-Busy CU
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Not able to add EE monitor on port 1 after firmware upgrade from 6.1.0c to 6.2.0 on 400 Multiprotocol router. Fixed in FOS 6.3.0 Nsinfo.htm returns NPIV info as Physical if non-VF switch is connected Fixed in FOS 6.3.0 to VF enabled platform. CP experienced a kenel panic "Oops: kernel access of bad area, sig: Fixed in FOS 6.3.0 11 [#1]". Fruclass in fru table and fruhistoryclass in fruhistorytable of HA MIB shows other(1) for CP slot instead of cp(4) for DC SAN Director and DC04 SAN Director. Fixed in FOS 6.3.0 CPstatus change trap is not generated on issuing HA failover for 4/256 SAN Director, but the failover happens and the CP status change oid Fixed in FOS 6.3.0 returns changed values. FOS CLI doesn't allow Port fencing policy addition for F_Port when there are no F_ports on the switch. Fixed in FOS 6.3.0 Workaround prior to code change: A. DCFM can be used to add the port fencing policy for F_Port. B. Existing FOS CLI can always be used to add port fencing policy after bringing up F_Port on a switch. Adding port fencing policy for F_Port makes sense only when there are F ports on a switch and anyway the existing CLI behaviour takes care of this. Not getting GbE ports while performing EnumerateAssociatedInstances Fixed in FOS 6.3.0 on Brocade_LogicalSwitch. Switch doesn't commit after firmwareDownload fail as 0x23 (time out). Fixed in FOS 6.3.0 Appropriate message is not shown in the message box, when the "Details" button in the "Service" tab of "HA" window is clicked. Fixed in FOS 6.3.0 High Availability: The error message thrown is not relevant or meaningful, when the values for E_D_TOV and R_D_TOV in the "Configure" Fixed in FOS 6.3.0 tab of "Switch admin", are changed. Incorrect output from agshow command. Fixed in FOS 6.3.0 Detected termination of zoned observed running repeated multiple zone updates for several hours in different FIDs. Fixed in FOS 6.3.0 FICON FCIP Acceleration error - FCCU LinkBusy from non-Busy CU in Fixed in FOS 6.3.0 ReadStates. Found 2 LUNs got disabled with "Rekey done with failure" after overnight manual_rekey finished. [CVLC-1001], 775/57, SLOT 2 | FID 128, Nept_74, Manual re-key failed, LUN SN. Fixed in FOS 6.3.0 Workaround prior to code change: Re-enable LUN. With Safezoning disabled, enabling defaultzoning via WT post concerning messages that Safezoning was disable and defaultzoning was Fixed in FOS 6.3.0 enabled. 62