HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 72

downloads HCL on an HP StorageWorks DC SAN Director fails on, Solution, Closed defect summary

Page 72 highlights

Closed defect summary Solution With an HP StorageWorks 1606 SAN Extension Switch and an Multiprotocol Extension Blade, smart data for GE-type ports (such as SFP temperature and power) are not updated in sfpshow by the automatic polling loop. Fixed in FOS 6.3.0b supportsave does not capture information for FIDs with index >3. Fixed in FOS 6.3.0b On an 8 Gb switch in Access Gateway mode connected to another switch running FOS 6.2.x or earlier, links on the Access Gateway device enter a disabled state and report NPIV not supported by Fabric port, even though the edge switch port has NPIV enabled. Fixed in FOS 6.3.0b With either the 2408 FCoE Switch or the 10/24 FCoE Blade, when selecting FCoE Login in the Element Manager under switch admin, the error message FCoE Login Management is disabled in the switch, make sure you enabled it to view the chassis appears. Fixed in FOS 6.3.0b On an HP StorageWorks DC SAN Director Switch Multiprotocol Extension Blade or 1606 Extension Switch, the portdisable xge0 CLI command does not disable the port, even though the RAS log and switchshow list it as disabled. Fixed in FOS 6.3.0b FICON emulation mode fails when trying to vary paths online to extended DASD devices with MVS IOS444I error messages. Fixed in FOS 6.3.0b Workaround prior to upgrade: Disable FICON XRC Emulation. In a fabric with more than 50 switches, non-disruptive firmware downloads (HCL) on an HP StorageWorks DC SAN Director fails on the standby CP. Fixed in FOS 6.3.0b Workaround prior to upgrade: Rerun firmwaredownload. Excessive internal messages cause a RASLOG flood condition and a weblinkerfcg message appears on FCIP switches in the fabric (HP StorageWorks 1606 Extension SAN Switch and Multiprotocol Extension Blade). This can lead to other important RASLOG messages being lost. This condition occurs with IPSEC, which is not supported in this release. Fixed in FOS 6.3.0b HP StorageWorks DC SAN Director panicks and reboots after anfwshow --disable --port command is issued. Fixed in FOS 6.3.0b SMI fails to discover all switches over EX_Port after an hafailover, and reports LOGIN FAILED after the GPL2 query targeted to the translate domain is rejected. Fixed in FOS 6.3.0b After upgrading from FOS 6.2.0g to 6.3.0, LDAP certificates are missing and you may not be able to log in to the switch using LDAP authentication. The degree to which the user is locked out depends on how the LDAP environment was set up. Fixed in FOS 6.3.0b workaround prior to upgrade: Log in using a serial console and reimport the LDAP certificate(s). After an HCL firmware upgrade, device connectivity is lost when the Fixed in FOS 6.3.0b zone is enabled on an HP StorageWorks 1606 Extension SAN Switch. When a switch running FOS 5.2.x sends an internal query to directors that were not properly set up to handle switches with more than 256 Fixed in FOS 6.3.0b ports, a segmentation fault causes a CALD panic in the fabric. 72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Solution
Closed defect summary
Fixed in FOS 6.3.0b
With an HP StorageWorks 1606 SAN Extension Switch and an Mul-
tiprotocol Extension Blade, smart data for GE-type ports (such as SFP
temperature and power) are not updated in
sfpshow
by the automatic
polling loop.
Fixed in FOS 6.3.0b
supportsave
does not capture information for FIDs with index >3.
Fixed in FOS 6.3.0b
On an 8 Gb switch in Access Gateway mode connected to another
switch running FOS 6.2.x or earlier, links on the Access Gateway
device enter a disabled state and report
NPIV not supported by
Fabric port
, even though the edge switch port has NPIV enabled.
Fixed in FOS 6.3.0b
With either the 2408 FCoE Switch or the 10/24 FCoE Blade, when
selecting
FCoE Login
in the Element Manager under switch admin,
the error message
FCoE Login Management is disabled in
the switch, make sure you enabled it to view the
chassis
appears.
Fixed in FOS 6.3.0b
On an HP StorageWorks DC SAN Director Switch Multiprotocol Exten-
sion Blade or 1606 Extension Switch, the
portdisable xge0
CLI
command does not disable the port, even though the RAS log and
switchshow
list it as disabled.
Fixed in FOS 6.3.0b
Workaround prior to upgrade:
Disable FICON XRC Emulation.
FICON emulation mode fails when trying to vary paths online to exten-
ded DASD devices with
MVS IOS444I
error messages.
Fixed in FOS 6.3.0b
Workaround prior to upgrade:
Rerun
firmwaredownload
.
In a fabric with more than 50 switches, non-disruptive firmware
downloads (HCL) on an HP StorageWorks DC SAN Director fails on
the standby CP.
Fixed in FOS 6.3.0b
Excessive internal messages cause a RASLOG flood condition and a
weblinkerfcg
message appears on FCIP switches in the fabric (HP
StorageWorks 1606 Extension SAN Switch and Multiprotocol Extension
Blade). This can lead to other important RASLOG messages being lost.
This condition occurs with IPSEC, which is not supported in this release.
Fixed in FOS 6.3.0b
HP StorageWorks DC SAN Director panicks and reboots after
an
fwshow --disable --port
command is issued.
Fixed in FOS 6.3.0b
SMI fails to discover all switches over EX_Port after an
hafailover
,
and reports
LOGIN FAILED
after the GPL2 query targeted to the
translate domain is rejected.
Fixed in FOS 6.3.0b
workaround prior to upgrade:
Log in using a serial console and
reimport the LDAP certificate(s).
After upgrading from FOS 6.2.0g to 6.3.0, LDAP certificates are
missing and you may not be able to log in to the switch using LDAP
authentication. The degree to which the user is locked out depends on
how the LDAP environment was set up.
Fixed in FOS 6.3.0b
After an HCL firmware upgrade, device connectivity is lost when the
zone is enabled on an HP StorageWorks 1606 Extension SAN Switch.
Fixed in FOS 6.3.0b
When a switch running FOS 5.2.x sends an internal query to directors
that were not properly set up to handle switches with more than 256
ports, a segmentation fault causes a CALD panic in the fabric.
72