HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 18

Fibre Channel Routing scalability, StorageWorks SAN Design Reference Guide

Page 18 highlights

IMPORTANT: Director blades must meet the minimum FOS levels to operate in the Director chassis. For example, the FC8-32 is not supported in the 4/256 SAN Director with FOS 6.0.x. Table 4 Power supplies required for blades in Director chassis Director blade 4/256 SAN Director FC4-16 FC4-32 FC4-48 FC8-16 FC8-32 Two power supplies DC SAN Backbone Director and DC04 SAN Director Two power supplies1 FC8-48 FC10-6 Four power supplies Two power supplies2 FR4-18i (FCIP/FC Router blade) Four power supplies FC4-16IP (iSCSI blade) Two power supplies. The FC4-16IP blades are not supported in the DC SAN Backbone Director or DC04 SAN Director.2 FS8-18 (DC Switch Encryption FC Blade) FX8-24 (DC SAN Director Multiprotocol Extension Blade) FCOE10-24 (DC SAN Director Switch 10/24 FCoE Blade) Not supported Two power supplies. For the DC SAN Backbone Director with three or more FS8-18 blades, (2+2) 220 VAC power supplies are required for redundancy. For one or two FS8-18 blades, only two power supplies are required for redundancy. For the DC04 SAN Director, only two 220 VAC power supplies are required for redundancy with any number of FS8-18 blades. For the DC SAN Backbone Director or DC04 SAN Director, only two 220 VAC power supplies are required for redundancy with FX8-24 blades.2 1The FC blades in this row are the only ones supported in the DC SAN Backbone Director or DC04 SAN Director with 110 VAC power supplies. 2110 VAC is not supported in either the DC SAN Backbone Director or DC04 SAN Director with these blades. Fibre Channel Routing scalability For the latest information about Fibre Channel Routing (FCR) scalability support, see the HP StorageWorks SAN Design Reference Guide, available at: http://www.hp.com/go/sandesignguide 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

IMPORTANT:
Director blades must meet the minimum FOS levels to operate in the Director chassis. For example,
the FC8-32 is not supported in the 4/256 SAN Director with FOS 6.0.x.
Table 4 Power supplies required for blades in Director chassis
DC SAN Backbone Director and
DC04 SAN Director
4/256 SAN Director
Director blade
Two power supplies
1
Two power supplies
FC4-16
FC4-32
FC4-48
FC8-16
FC8-32
Two power supplies
2
Four power supplies
FC8-48
FC10-6
Two power supplies. The FC4-16IP
blades are not supported in the DC
SAN Backbone Director or DC04
SAN Director.
2
Four power supplies
FR4-18i (FCIP/FC Router blade)
FC4-16IP (iSCSI blade)
Two power supplies. For the DC
SAN Backbone Director with three
or more FS8-18 blades, (2+2) 220
VAC power supplies are required
for redundancy. For one or two
FS8-18 blades, only two power
supplies are required for
redundancy. For the DC04 SAN
Director, only two 220 VAC power
supplies are required for
redundancy with any number of
FS8-18 blades.
For the DC SAN Backbone Director
or DC04 SAN Director, only two
220 VAC power supplies are
required for redundancy with
FX8-24 blades.
2
Not supported
FS8-18 (DC Switch Encryption FC
Blade)
FX8-24 (DC SAN Director
Multiprotocol Extension Blade)
FCOE10-24 (DC SAN Director
Switch 10/24 FCoE Blade)
1
The FC blades in this row are the only ones supported in the DC SAN Backbone Director or DC04 SAN Director with 110
VAC power supplies.
2
110 VAC is not supported in either the DC SAN Backbone Director or DC04 SAN Director with these blades.
Fibre Channel Routing scalability
For the latest information about Fibre Channel Routing (FCR) scalability support, see the
HP
StorageWorks SAN Design Reference Guide
, available at:
h
t
tp://w
w
w
.hp
.co
m/go/s
ande
si
gngui
de
18