HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 57

In Access gateway mode, Port swap and Enable/Disable NPIV option

Page 57 highlights

In Access gateway mode,Port swap and Enable/Disable NPIV option Fixed in FOS 6.3.0 is enabled in WebTools. As DCFM polling LUNs, the memory usage for weblinker is increased. Fixed in FOS 6.3.0 FDMI: fdmid crashes when a brocade HBA with virtual ports is connected to a 4/256 SAN Director. Fixed in FOS 6.3.0 Workaround prior to code change: Logout all the devices registered their HBA info and log them in after the fabric is stable. Brocade 8000 firmware download hot code load shows no identifier Fixed in FOS 6.3.0 in the HTML page. Unable to activate a new PDCM Matrix with WebTools. Fixed in FOS 6.3.0 Workaround prior to code change: Activate the same PDCM Matrix from WebTools, with "Active=Save Mode" checked from 'Edit CUP Port Connectivity Configuration' window. VCM don't have GUI capability to change SNMP read community configuration. 8/80 SAN Switch: Removing any power supply FRU causes fans to speed up for a short period (which is not expected). The SFP parameters are not returning for the ports which are under the logical switches other than the default logical switch. ptsupportshow -all does not function properly. Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 Fixed in FOS 6.3.0 Workaround prior to code change: Specify the slot number for which the command is directed. For example, ptsupportshow 1 -all command to see all ports on blade 1. WEBLINKERFCGD core files after weekend SAK/IRNDUP run on DC04 Fixed in FOS 6.3.0 SAN Director. Applications cannot distinguish between Multiprotocol Router Blade and Core blades on DC SAN Director using SNMP. Need to add two Fixed in FOS 6.3.0 new FRU classes: "coreblade" and "applicationblade" class. Switch panic in ficon enviormnet when blocking/unblocking E-Port due Fixed in FOS 6.3.0 to RNID data count is incorrect. Switch Admin: when user moves to a different tab without applying changes, no warning is displayed. Fixed in FOS 6.3.0 Performance Monitoring: Error message is shown when launching SCSI Read/Write on a LUN Per port graph. Fixed in FOS 6.3.0 Enabled minimum FOS support for DWDM-SFP port media. Fixed in FOS 6.3.0 Re-keys are getting stuck. Fixed in FOS 6.3.0 HP StorageWorks FOS 6.3.0b Release Notes 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Fixed in FOS 6.3.0
In Access gateway mode,Port swap and Enable/Disable NPIV option
is enabled in WebTools.
Fixed in FOS 6.3.0
As DCFM polling LUNs, the memory usage for weblinker is increased.
Fixed in FOS 6.3.0
Workaround prior to code change:
Logout all the devices registered their
HBA info and log them in after the
fabric is stable.
FDMI: fdmid crashes when a brocade HBA with virtual ports is connec-
ted to a 4/256 SAN Director.
Fixed in FOS 6.3.0
Brocade 8000 firmware download hot code load shows no identifier
in the HTML page.
Fixed in FOS 6.3.0
Workaround prior to code change:
Activate the same PDCM Matrix from
WebTools, with
Active=Save Mode
checked from
Edit CUP Port
Connectivity Configuration
window.
Unable to activate a new PDCM Matrix with WebTools.
Fixed in FOS 6.3.0
VCM don
t have GUI capability to change SNMP read community
configuration.
Fixed in FOS 6.3.0
8/80 SAN Switch: Removing any power supply FRU causes fans to
speed up for a short period (which is not expected).
Fixed in FOS 6.3.0
The SFP parameters are not returning for the ports which are under
the logical switches other than the default logical switch.
Fixed in FOS 6.3.0
Workaround prior to code change:
Specify the slot number for which the
command is directed. For example,
ptsupportshow 1 -all command to see
all ports on blade 1.
ptsupportshow -all does not function properly.
Fixed in FOS 6.3.0
WEBLINKERFCGD core files after weekend SAK/IRNDUP run on DC04
SAN Director.
Fixed in FOS 6.3.0
Applications cannot distinguish between Multiprotocol Router Blade
and Core blades on DC SAN Director using SNMP. Need to add two
new FRU classes: "coreblade" and "applicationblade" class.
Fixed in FOS 6.3.0
Switch panic in ficon enviormnet when blocking/unblocking E-Port due
to RNID data count is incorrect.
Fixed in FOS 6.3.0
Switch Admin: when user moves to a different tab without applying
changes, no warning is displayed.
Fixed in FOS 6.3.0
Performance Monitoring: Error message is shown when launching
SCSI Read/Write on a LUN Per port graph.
Fixed in FOS 6.3.0
Enabled minimum FOS support for DWDM-SFP port media.
Fixed in FOS 6.3.0
Re-keys are getting stuck.
HP StorageWorks FOS 6.3.0b Release Notes