HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 44
After changing FID on HP StorageWorks 8/40 SAN Switch and then, HA cluster member node
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
With McDATA default zone enabled, when numerious NPIV devices in the default zone come online at the same instant, some devices were missing from portcam table. Fixed in FOS 6.3.0 Workaround prior to code change: This is due to multiple devices logging in simultaneously. So apply portdisable to all ports connected to the devices and apply portenable sequentially. This will resolve the issue. NPIV devices in Interopmode 2 default zone is not supported. NPIV devices should be part of the active zone configuration. Fabric mode TT does not show all the flows when device port is disabled and enabled back after TT monitor installation. Fixed in FOS 6.3.0 If using WebTools to perform cfgsaveactivetodefined with a zone file close to the maximum size in an interop mode fabric with more than 20 switches, the weblinker process may get terminated. Fixed in FOS 6.3.0 In a mixed fabric of VF enabled and non-VF switches, a VF enabled switch may not be able to detect the FID conflict with the other VF enabled switch, if there are non-VF switches in the path interconnecting the VF enabled switches. Fixed in FOS 6.3.0 Workaround prior to code change: Follow the raslog errors FABR-1044 or FABR-1043 displayed by switches in the fabric to identify the offending switch and resolve the FID conflict. IPC message from module CALD to Management Server is dropped Fixed in FOS 6.3.0 by Management server. This causes CALD module to wait indefinitely. Sometimes config file downloaded may cause the configdownload command to crash. Fixed in FOS 6.3.0 Workaround prior to code change: Disable the switch and then attempt configdownload. After changing FID on HP StorageWorks 8/40 SAN Switch and then performing switchenable, switchdisable, observed ASSERT. Fixed in FOS 6.3.0 Workaround prior to code change: Do not disable a switch immediately after enabling, if it's coming up with a new FID for the first time. Wait for sometime (at least 10 s) before issuing switch disable. HA cluster member node, HP StorageWorks Encryption SAN Switch faults as a result of slot powercycling its HA cluster peer (HP StorageWorks DC Encryption FC Blade). Fixed in FOS 6.3.0 Workaround prior to code change: Reboot the Encryption SAN Switch. IPL file is not getting updated, when a PDCM matrix is activated using Fixed in FOS 6.3.0 WebTools with "Active=Save Mode" checked. Fabric Watch failed to initialize on fully populated HP StorageWorks Fixed in FOS 6.3.0 DC SAN Backbone Director. Memory leak when querying connUnitPortFCId in Access Gateway (AG) mode and also when querying FcFeModuleName. Fixed in FOS 6.3.0 Workaround prior to code change: Avoid querying FcFeModuleName or (connUnitPortFCId in AG mode) MIB to avoid memory leak. 44