HP StorageWorks 1606 HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, Apri - Page 45
Supportsave slot transfer failed for HP StorageWorks DC Switch En
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Occasionally during the firmware upgrade process, the 1250 processor is still rebooting when the FCR routes are being processed, resulting Fixed in FOS 6.3.0 in missing FCR routes and an inability to route traffic across VEX ports. CUP Port present CU-Busy on one path and never sending CU-End to Fixed in FOS 6.3.0 clear busy. In B2E routed environment, when user executes Pathinfo command in Fixed in FOS 6.3.0 BB querying for xlate domain, the switch may panic. Observed kernel panic on a DC SAN Backbone Director in RTE module. Fixed in FOS 6.3.0 Switches leaking memory slowly over extended period while being managed by DCFM. Fixed in FOS 6.3.0 Switchdisabling all switches in the fabric causing all HP StorageWorks 4/256 SAN Director switches 'Out of Memory: Killed process 2337 Fixed in FOS 6.3.0 (iswitchd)'. License problem observed after configdownload and QoS license was Fixed in FOS 6.3.0 checked for 4G platforms at CLI. Unable to configure ports using configdownload. Fixed in FOS 6.3.0 Portcams's and NS zonemembership data are missing for hard-zoned Fixed in FOS 6.3.0 ports. Software was not enforcing a mandatory switch disable before config- Fixed in FOS 6.3.0 uring the backbone Fabric ID. Failover when Logical Switch (LS) trans incomplete Observed and Panic. Ficud terminated detected when FID is created Fixed in FOS 6.3.0 Workaround prior to code change: Don't use logical switches. ISMIC - When a reset of a HP-VC is done via the OA, the vcfcadm_ user password is NOT generated as seen from the console log, thereby causing a NO COMM on the VCM. Fixed in FOS 6.3.0 Workaround prior to code change: Power off and Power on the Switch via OA should fix the problem. Swapping HP StorageWorks 32 port 8Gb FC blade with 48 port blade in DC04 SAN Director initializes both to a Faulty-51 state. Fixed in FOS 6.3.0 Workarounds prior to code change: 1. Slotpoweroff and slotpoweron always recovers the blades. 2. DC04 SAN Director reboots also recover the blades. Supportsave slot transfer failed for HP StorageWorks DC Switch Encryption blade after FAULTY (79) code Fixed in FOS 6.3.0 8Gb storage device failed to detect 8Gb speed when port was locked as a G_port. Fixed in FOS 6.3.0 Workaround prior to code change: Instead of relying on auto-negotiation, lock the switch port at 8Gb. HP StorageWorks FOS 6.3.0b Release Notes 45