Honeywell Heat/1Cool User Guide - Page 105

Wesco/addison

Page 105 highlights

WESCO/ADDISON Models: WPH022, 028, 032, 036, 044, 054, 064. WRH022, 028, 032, 036, 044, 054, 064. WSH028, 032, 036, 042. DWPG024, 030, 036, 042, 048, 054, 060, 066. HWPG012, 017, 020, 024, 030, 036, 042, 048, 054, 060, 066. VWPG017, 020, 024, 030, 036, 042, 048, 054, 060, 066. Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1712 Y594R1425 Y5Y9549G41G4174619 T8T681611G11R0100400 T8T481411R11R0120802 T8T581511G11G0140721 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Function Existing Terminals Common ´ or C1 C X X X C C C C C C Power R R Compressor or W1 Y Y 1st Stage - - Heat Auxiliary or or W1 W2 W2 W2 Heat R Y ² W1 R Y1 ² W1 R or Y1 Y ² W1 W2 W2 W2 R Y ² W1 R Y1 ² W1 W2 W2 R Y ² W1 W2 R R Y1 ² W1 Y1/W1 - · W2 Aux. Fan G G C/O Valve - B Heat C/O Valve or Y1 O O Cool System Monitor/ X System Defrost G G B B O O ¿ L G G G G G G ³ or ³ or ³ B B B O/B B B O/B O/B or ³ ³ or ³ O O O O/B O O O/B O/B ¶ ¶ ¿ ¶ ¿ ¿ L L L L L L EM. Heat E E E E E E E E E E Multiple Aux. - W3 W3 W3 - Heat Loads » - - - - - LED Indication - 2nd Stage - Compressor - X2 X1 X2 X1 X2 - - - - - - - - - X1 X2 - · - - W2 2nd Stage - - - - - - - - - Cool ³ Configure O/B (select models) in Installer Setup. · When W2 is not used, configure W2 cycle rate to NC. » Terminal is for multiple auxiliary heat loads such as contactors, sequencers, or relays. ¿ LED is energized when terminal is powered. ´ Terminal must be connected to the transformer common. ² Do not remove factory-installed jumper. ¶ L terminal is powered continuously in Em. Ht. position. Y2 M13222 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T872G1265/Q672F1265 T874G1287/Q6741253 T872G1281/Q672F1265 T874G1543/Q674F1345 (403-197) T872R1016/Q672B1103 T874R1012/Q674B1109 T874C1315 70-6627 • 103

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
103
WESCO/ADDISON
Models: WPH022, 028, 032, 036, 044, 054, 064. WRH022, 028, 032, 036, 044, 054, 064. WSH028, 032, 036, 042. DWPG024, 030, 036, 042,
048, 054, 060, 066. HWPG012, 017, 020, 024, 030, 036, 042, 048, 054, 060, 066. VWPG017, 020, 024, 030, 036, 042, 048, 054, 060, 066.
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T872G1265/Q672F1265
T872G1281/Q672F1265
T872R1016/Q672B1103
T874C1315
T874G1287/Q6741253
T874G1543/Q674F1345 (403-197)
T874R1012/Q674B1109
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1712
T8611R1000
T8611G1004
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Configure O/B (select models) in Installer Setup.
B
When W2 is not used, configure W2 cycle rate to NC.
C
Terminal is for multiple auxiliary heat loads such as contactors, sequencers,
or relays.
Common
E
Power
Compressor
1st Stage
Heat
Auxiliary
Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
EM. Heat
Multiple Aux.
Heat Loads
C
LED
Indication
2nd Stage
Compressor
2nd Stage
Cool
M13222
D
LED is energized when terminal is powered.
E
Terminal must be connected to the transformer common.
F
Do not remove factory-installed jumper.
G
L terminal is powered continuously in Em. Ht. position.
F
F
F
F
A
A
A
A
A
A
F
B
G
D
G
D
G
D
B
F
F
D
C1
or
C
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
W1
or
Y
Y
Y
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W1
or
W2
or
W2
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
Y1
or
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
X
L
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
E
W3
W3
W3
X2
X1
X2
X1
X2
X1
X2
W2
Y2
Chronotherm
IV
Y594R1425
Y594G1419
Y594G1476