Honeywell Heat/1Cool User Guide - Page 45

Function, Chronotherm, Electronic Replacement or Upgrade, Electromechanical, Chronotherm IV

Page 45 highlights

Electromechanical Chronotherm® III CARRIER TYPICAL 38BQ » Electronic Replacement or Upgrade Chronotherm IV Q6T78474F1D0121265/ T8611M7008 T8511M1002 T8T6816111M2M0220517 W89P00C8B910000/2 Function Existing Terminals Common ³ C X1 C C C C Power R R R R R R 1st Stage Cool Y1 » Y1 » » » » » 1st Stage Heat W1 W1 » » » » · 2nd Stage Heat W2 W2 W2 Y2 Y2 W2 Fan G G C/O Valve - O Cool » G » O G »´ O/B G »´ O/B G »´ O/B C/O Valve - Heat Em. Heat E Common 1st Stage - Compressor » System Monitor/ - System Defrost LED Indication X B · E - - X2 · B E » Y L¶ X1 X2 ¿ O/B E Y1 » Lº - O/B E Y1 » L¶ X1 X2 ¿ O/B E Y1/W1 »² Lº - 2nd Stage Cool Y2 Y2 Y2 Y2 Y2 Y2 ³ Terminal must be connected to the transformer common. · For auxiliary heat LED indication, jumper X2 to W2 on Q674. For emergency heat LED indication, jumper X2 to E. » Relay required (R8222B1067 typically) for T8511M, T8611M, PC8900/W8900B1002 application. See page 9 for wiring diagram. ¿ Optional LED indication activated with completed circuit on X1 and X2 terminals. ´ Configure O/B (select models) in Installer Setup. ² Configure Y1/W1 terminal in installer setup. ¶ L terminal is continuously energized in Em. Heat Mode. º LED is energized when terminal is powered. M13148 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T874D1074/Q674F1030 (HHO7AT172/HH93AZ174) T874D1074/Q674F1063 (HH07AT172/HH93AZ181) 70-6627 • 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
43
CARRIER
TYPICAL 38BQ
C
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T874D1074/Q674F1030 (HHO7AT172/HH93AZ174)
T874D1074/Q674F1063 (HH07AT172/HH93AZ181)
T8611M2017
T8611M2025
Function
Existing
Terminals
T8611M7008
T8511M1002
Chronotherm
®
III
Electronic Replacement or Upgrade
Common
A
Power
1st Stage Cool
1st Stage Heat
2nd Stage Heat
Fan
C/O Valve
Cool
C
C/O Valve
Heat
Em. Heat
Common 1st Stage
Compressor
C
System Monitor/
System Defrost
LED Indication
2nd Stage Cool
M13148
C
C
B
C
C
C
A
Terminal must be connected to the transformer common.
B
For auxiliary heat LED indication, jumper X2 to W2 on Q674. For emergency
heat LED indication, jumper X2 to E.
C
Relay required (R8222B1067 typically) for T8511M, T8611M,
PC8900/W8900B1002 application. See page 9 for wiring diagram.
D
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
E
Configure O/B (select models) in Installer Setup.
F
Configure Y1/W1 terminal in installer setup.
G
L terminal is continuously energized in Em. Heat Mode.
H
LED is energized when terminal is powered.
PC8900/
W8900B1002
B
Electromechanical
T874D1165/
Q674F1022
B
D
D
CF
C
CE
CE
CE
Chronotherm IV
C
X1
C
C
C
C
R
R
R
R
R
R
Y1
Y1
W1
W1
W2
W2
W2
Y2
Y2
W2
G
G
G
G
G
G
O
O
O/B
O/B
O/B
B
B
O/B
O/B
O/B
E
E
E
E
E
E
Y
Y1
Y1
Y1/W1
L
L
L
L
X
X2
X1
X2
X1
X2
Y2
Y2
Y2
Y2
Y2
Y2
H
G
H
G
C
C
C
C
C
C
C
C