Honeywell Heat/1Cool User Guide - Page 38

Amana - heat cool parts

Page 38 highlights

AMANA Models: RHA1842A, RHA (24-42)A2A, RHA (48-60)A2A, RHA (36, 48, 60)A3A & A4A, RHD (18-24)A2A, RHD (30-60)A2A, RHE (18-24)A2A, RHE (30-60)A2A, RHA (36, 48, 60)A3B & A4B. Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1712 Y594R1425 Y5Y95494G1G4174619 T8T681611R11G0100004 T8T481411R11R0120802 T8T5815111G1G0140721 T8T081011R11R0110406 T8T6816111G2G0220802 W890P0CB8190000/2 Existing Function Terminals or or Common » X X1 C X X X Power R R R R Compressor Y Y · 1st Stg. Heat W1 - Y · W1 Y1 · W1 Aux. Heat W2 W2 W2 W2 Fan G G G G C/O Valve O O O O Cool C/O Valve B B B B Heat Em. Heat E E ³ System Monitor/ L System Defrost ³ Multiple Aux. W3 W3 Heat Loads LED Indication - - ³ Defrost P - E E µ L W3 W3 ´ X2 X1 X2 - - 2nd Stage - - - - Compressor 2nd Stage - - - - Cool ³ Not available on all models. · Do not remove factory-installed jumper. » Terminal must be connected to the transformer common. ¿ If separate Y1 and W1 terminals are required, install R8222D1014. See page 12. ´ Field-installed X2 to X jumper. C R or Y1 Y · W1 W2 G O B C C C C C R R Y Y1 · · W1 W1 W2 W2 R Y · W1 W2 R Y1 · W1 W2 R ¿ Y1/W1 - ¾ Aux. G G G or º O O O/B O or º B B O/B B G or º O O/B or º B O/B G º O/B º O/B E ² L ¶ E E E E E ² µ ² µ µ L L L L L ¶ ¶ ¶ ¶ ¶ X1 X2 - - - - - - - - - X1 X2 - - - - ¾ - - W2 - - - - - Y2 ² L terminal is powered continuously when thermostat is in Em. Ht. position. ¶ If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. º Configure O/B (select models) in Installer Setup. ¾ When W2 is not used, configure W2 cycle rate to NC. µ LED is energized when terminal is powered. M13172 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T841A1241 (D99458003) T8611R1083 (D9807605) T874R1194/Q674L1249 70-6627 • 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
36
AMANA
Models: RHA1842A, RHA (24-42)A2A, RHA (48-60)A2A, RHA (36, 48, 60)A3A & A4A, RHD (18-24)A2A, RHD (30-60)A2A,
RHE (18-24)A2A, RHE (30-60)A2A, RHA (36, 48, 60)A3B & A4B.
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T841A1241 (D99458003)
T8611R1083 (D9807605)
T874R1194/Q674L1249
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1712
T8611G1004
T8611R1000
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
A
I
A
Not available on all models.
B
Do not remove factory-installed jumper.
C
Terminal must be connected to the transformer common.
D
If separate Y1 and W1 terminals are required, install R8222D1014.
See page 12.
E
Field-installed X2 to X jumper.
A
Common
C
Power
Compressor
1st Stg. Heat
Aux. Heat
Fan
C/O Valve
Cool
C/O Valve
Heat
Em. Heat
System Monitor/
System Defrost
Multiple Aux.
Heat Loads
LED
Indication
Defrost
2nd Stage
Compressor
2nd Stage
Cool
B
E
H
G
H
H
H
H
H
M13172
B
B
B
B
B
B
D
B
G
G
G
G
G
F
L terminal is powered continuously when thermostat is in Em. Ht. position.
G
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
H
Configure O/B (select models) in Installer Setup.
I
When W2 is not used, configure W2 cycle rate to NC.
J
LED is energized when terminal is powered.
F
J
F
J
J
J
F
I
Chronotherm
IV
X
or
X1
or
C
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
Y
Y
Y
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
B
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
E
E
E
E
E
E
E
E
E
E
L
L
L
L
L
L
L
L
W3
W3
W3
W3
X2
X1
X2
X1
X2
X1
X2
P
W2
Y2
Y594R1425
Y594G1419