Honeywell Heat/1Cool User Guide - Page 111

Williamson

Page 111 highlights

Electromechanical Chronotherm® III WILLIAMSON COOLING CHANGEOVER Electronic Replacement or Upgrade Chronotherm IV T841A1712 Y594R1425 Y5Y95494G1G4174619 T8T6816111G1R0100400 T8T481411R11R0120802 T8T5815111G1G0140721 T8T081011R11R0110406 T8T6816111G2G0220802 W890P0CB8190000/2 Function Existing Terminals Common ² X X X X C C C C C C Power R Compressor Y 1st Stage - Heat Aux. Heat W2 R R R R R R R R R or Y Y Y1 Y1 Y Y Y1 Y Y1 Y1/W1 ¶ ¶ ¶ ¶ ¶ ¶ ¶ - W1 W1 W1 W1 W1 W1 W1 - · W2 W2 W2 W2 W2 W2 W2 W2 Aux. Fan G C/O Valve - Heat C/O Valve O Cool System Monitor/ L System Defrost G G G B B B O O O µ L G B O ¸ L G G ᕡ or B B O/B ᕡ or O O O/B ¸ µ L L G G ᕡ or B B O/B ᕡ or O O O/B ¸ µ L L G ᕡ O/B ᕡ O/B µ L Em. Heat E E E E E E E E E E Multiple Aux. Heat Loads » W3 LED Indication A 2nd Stage - Compressor W3 W3 W3 ´ ´ ´ - X2 ¾ X1 X2 ¿ X1 X2 º - - - - - - - - ´ ´ ´ ¿ - X1 X2 - · - - W2 2nd Stage - - - - - - - - - Y2 Cool ³ Configure O/B (select models) in Installer Setup. · When W2 is not used, configure W2 cycle rate to NC. » Terminal is for multiple auxiliary heat loads such as contactors, sequencers, or relays. ¿ Optional LED indication activated with completed circuit on X1 and X2 terminals. ´ If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. ² Terminal must be connected to the transformer common. ¶ Do not remove factory-installed jumper. º Optional Check LED on T8611G1004. See Fig. 26. ¾ Field-installed X2 to X (C) jumper. µ LED is energized when terminal is powered. ¸ L terminal is powered continuously when thermostat is in Em. Ht. position. M13213 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER T874C1570/Q674B1000 T874L1455/Q674L1322 T874R1236/Q674L1348 T874R1392/Q674L1447 70-6627 • 109

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
109
WILLIAMSON
COOLING CHANGEOVER
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER
T874C1570/Q674B1000
T874L1455/Q674L1322
T874R1236/Q674L1348
T874R1392/Q674L1447
Common
F
Power
Compressor
1st Stage
Heat
Aux. Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
Em. Heat
Multiple Aux.
Heat Loads
C
LED
Indication
2nd Stage
Compressor
2nd Stage
Cool
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1712
T8611R1000
T8611G1004
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Configure O/B (select models) in Installer Setup.
B
When W2 is not used, configure W2 cycle rate to NC.
C
Terminal is for multiple auxiliary heat loads such as contactors, sequencers,
or relays.
D
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
E
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
M13213
F
Terminal must be connected to the transformer common.
G
Do not remove factory-installed jumper.
H
Optional Check LED on T8611G1004. See Fig. 26.
I
Field-installed X2 to X (C) jumper.
J
LED is energized when terminal is powered.
K
L terminal is powered continuously when thermostat is in Em. Ht. position.
1
1
1
G
G
G
G
G
1
1
1
D
G
G
K
E
E
E
E
E
E
H
D
I
B
J
J
J
K
K
B
J
X
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
Y
Y
Y
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
L
L
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
E
W3
W3
W3
W3
A
X2
X1
X2
X1
X2
X1
X2
W2
Y2
Chronotherm
IV
Y594R1425
Y594G1419
Y594G1476