Existing, Terminals, AVAILABLE, T874C1018, PC8900, NOT AVAILABLE

Page 98 highlights

SQUARE D/SUN DIAL Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV AVAILNAOBTLE AVAILNAOBTLE Q6T78474F1C0120218/ T8611R1000 T8T481411R11R0120802 T8T5815111G1G0140721 T8T081011R11R0110406 T8T6816111G2G0220802 W890P0CB8190000/2 Function Common · Existing Terminals or or X X1 C X1 C C C C C C Power Compressor R or Y Y1 1st Stage W1 Heat Aux. Heat W2 R Y1 ³ W1 R or Y1 Y ³ W1 W2 W2 R Y ³ W1 R Y1 ³ W1 R Y ³ W1 W2 W2 W2 R Y1 ³ W1 R » Y1/W1 - ´ W2 Aux. NOT AVAILABLE NOT AVAILABLE Fan G C/O Valve B Heat C/O Valve O Cool System Monitor/ System Defrost Em. Heat L or K E LED Indication X2 2nd Stage - Compressor G G G G G G G or or B B B B O/B B B O/B O/B or or O O O O O/B O O O/B O/B ² X2 ¶ L ¶ ² ¶ L L L ² ² L L E E X2 - - E E - - E E E ¿ X1 X2 - - - W2 ´ 2nd Stage Y2 Y2 Y2 Cool ³ Remove factory-installed Y1 (Y) to W1 jumper. · Terminal must be connected to the transformer common. » If separate Y1 and W1 terminals are required, install R8222D1014; see page 12. ¿ Optional LED indication activated with completed circuit on X1 and X2 terminals. ´ When W2 is not used, configure W2 cycle rate to NC. ² LED is energized when terminal is powered. ¶ L terminal is powered continuously when thermostat is in Em. Ht. position. M13202 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T872C1525/Q672F1182 (HCD-2/HCB-1) T874C1224/Q674F1071 (63600-002-09/63600-002-11) 70-6627 • 96

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
96
SQUARE D/SUN DIAL
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T872C1525/Q672F1182
(HCD-2/HCB-1)
T874C1224/Q674F1071
(63600-002-09/63600-002-11)
Common
B
Power
Compressor
1st Stage
Heat
Aux. Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
Em. Heat
LED
Indication
2nd Stage
Compressor
2nd Stage
Cool
T8011R1006
T8011R1014
Function
Existing
Terminals
NOT
AVAILABLE
NOT
AVAILABLE
T874C1018/
Q674F1022
T8611R1000
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Remove factory-installed Y1 (Y) to W1 jumper.
B
Terminal must be connected to the transformer common.
C
If separate Y1 and W1 terminals are required, install R8222D1014; see page 12.
D
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
M13202
E
When W2 is not used, configure W2 cycle rate to NC.
F
LED is energized when terminal is powered.
G
L terminal is powered continuously when thermostat is in Em. Ht. position.
A
A
A
A
A
A
F
G
F
E
G
F
E
D
C
G
F
X
or
X1
or
C
X1
C
C
C
C
C
C
R
R
R
R
R
R
R
R
Y
or
Y1
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
L
X2
L
L
L
L
L
L
K
or
E
E
E
E
E
E
E
E
X2
X2
X1
X2
W2
Y2
Y2
Y2
NOT AVAILABLE
NOT AVAILABLE
Chronotherm
IV