Honeywell Heat/1Cool User Guide - Page 107

Typical Hb, Hi Reli, Hlo

Page 107 highlights

Electromechanical Chronotherm® III WESTINGHOUSE TYPICAL HB, HI RELI, HLO Electronic Replacement or Upgrade Chronotherm IV AVAILNAOBTLE Y594R1425 Y5Y9549G41G4174619 T8611R1000 T8T481411R11R0120802 T8T581511G11G0140721 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Function Common ᕢ Existing Terminals X X X C C C C C C Power R R R R R R R R R 1st Stage W1 Heat 2nd Stage W2 Heat W1 W1 W1 W1 W1 W1 W1 ¶ W2 W2 W2 W2 W2 W2 W2 Aux. NOT AVAILABLE Fan G 1st Stage Y Cool G G G ³ ³ ³ Y Y1 Y1 G G G G G ³ ³ ³ ³ ² Y Y1 Y Y1 Y1/W1 2nd Stage - Cool C/O Valve - Heat C/O Valve - Cool - - - - - - - Y2 or or B B B B B O/B B B O/B O/B or or O O O O O O/B O O O/B O/B System Monitor/ - System Defrost L X1 L L L L L L Em. Heat E E E E E E E E E Multiple Aux. - Heat Loads » W3 W3 ¿ ¿ ¿ ¿ ¿ ¿ LED Indication - X2 ´ X2 ´ - - - - X1 X2 - 2nd Stage - Compressor ¶ - - - - - - - W2 ³ Remove factory-installed Y1 (Y) to W1 (W) jumper. · Terminal must be connected to the transformer common. » Terminal is for multiple auxiliary heat loads such as contactors, sequencers, or relays. ¿ If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B) terminal. ´ Field-installed X2 to X (C) jumper. ² If separate Y1 and W1 terminals are required, install R8222D1014; see page 12. ¶ When W2 is not used, configure W2 cycle rate to NC. M13211 70-6627 • 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
105
WESTINGHOUSE
TYPICAL HB, HI RELI, HLO
Common
2
Power
1st Stage
Heat
2nd Stage
Heat
Fan
1st Stage
Cool
2nd Stage
Cool
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
Em. Heat
Multiple Aux.
Heat Loads
C
LED
Indication
2nd Stage
Compressor
T8011R1006
T8011R1014
Function
Existing
Terminals
NOT
AVAILABLE
T8611R1000
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Remove factory-installed Y1 (Y) to W1 (W) jumper.
B
Terminal must be connected to the transformer common.
C
Terminal is for multiple auxiliary heat loads such as contactors, sequencers,
or relays.
D
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
M13211
E
Field-installed X2 to X (C) jumper.
F
If separate Y1 and W1 terminals are required, install R8222D1014; see
page 12.
G
When W2 is not used, configure W2 cycle rate to NC.
A
G
F
D
D
D
D
D
D
A
A
G
E
E
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
W1
W1
W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
Y
Y
Y1
Y1
Y
Y1
Y
Y1
Y1/W1
Y2
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
L
X1
L
L
L
L
L
L
E
E
E
E
E
E
E
E
E
W3
W3
X2
X2
X1
X2
W2
A
A
A
A
Chronotherm
IV
NOT AVAILABLE
Y594R1425
Y594G1419
Y594G1476