Honeywell Heat/1Cool User Guide - Page 115

B2ch, B2ps, Eics, Eieb, Eihb, E2ch Alternate Replacements

Page 115 highlights

YORK/BORG WARNER B2CH, B2PS, EICS, EIEB, EIHB, E2CH (ALTERNATE REPLACEMENTS) Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1217 Y594R1425 Y5Y9549G41G4174619 T8T681611G11R0100400 T8T481411R11R0120802 T8T581511G11G0140721 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Function Existing Terminals Common º B X X X C C C C C C Power R R Compressor or Y Y1 Y ¾ 1st Stage Heat W1 - Auxiliary or W W2 W2 Heat R Y ¾ W1 R Y1 ¾ W1 R or Y1 Y ¾ W1 W2 W2 W2 R Y ¾ W1 R Y1 ¾ W1 W2 W2 R Y ¾ W1 W2 R R Y1 ¾ W1 Y1/W1 - · W2 Aux. Fan C/O Valve Heat C/O Valve Cool System Monitor/ System Defrost EM. Heat G ¹ H O X or E X G G G B B B O O ¿ L ¶ ¶ E E O ¿ X1 ¶ E G B O ´ L ¶ E G G ³ or B B O/B or ³ O O O/B ´ ¿ L L ¶ E ¶ E G G ³ or B B O/B ³ or O O O/B ´ ¿ L L ¶ E ¶ E G ³ O/B ³ O/B ¿ L ¶ E Multiple Aux. - W3 W3 W3 - Heat Loads » - - LED Indication T X² - X2 ¸ ¸ X2 X1 X2 µ - - 2nd Stage - - - - - - - Compressor - - - - X1 X2 - · - - W2 2nd Stage - - - - - - - - - Y2 Cool ³ Configure O/B (select models) in Installer Setup. · When W2 is not used, configure W2 cycle rate to NC. » Terminal is for multiple auxiliary heat loads such as contactors, sequencers, or relays. ¿ LED is energized when terminal is powered. ´ L terminal is powered continuously in Em. Ht. position. ² Tape off. Not used. ¶ Field-installed E to W2 jumper for improved performance in emergency heat. º Terminal must be connected to the transformer common. ¾ Do not remove factory-installed jumper. µ Optional Check LED on T8611G1004. See Fig. 26. ¸ Field-installed X2 to X (C) jumper. ¹ H terminal is not available on all models. Ƹ Using these thermostats with a W8045 Demand Defrost Control may cause customer complaints. If replacing a thermostat used on a W8045, see York/Borg Warner Direct Replacements. M13224 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T841A1274 (2TH11703324) T874G1345 (2TH11702624)1 T8141A1006 T872G1299/Q672L1177 1 T874G1402/Q674L1363 (2TH11702824) T8300A1037/Q6300A1044 (2ET11700124A) T872R1032/Q672L1011 1 T874G1428/Q674J1027 (6TH11702424)1 T8300A1144/Q6300A1044 (6ET11700124A) T874G1170/Q674J1027 (2TH11702424) T874R1046/Q674L1017 (2TH11702224)1 T8611R1018 (025-27655) T874G1196/Q674J1027 T874R1046/Q674L1272 (2TH11702224)1 70-6627 • 113

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
113
YORK/BORG WARNER
B2CH, B2PS, EICS, EIEB, EIHB, E2CH (ALTERNATE REPLACEMENTS)
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T841A1274 (2TH11703324)
T872G1299/Q672L1177 1
T872R1032/Q672L1011 1
T874G1170/Q674J1027 (2TH11702424)
T874G1196/Q674J1027
T874G1345 (2TH11702624)1
T874G1402/Q674L1363 (2TH11702824)
T874G1428/Q674J1027 (6TH11702424)1
T874R1046/Q674L1017 (2TH11702224)1
T874R1046/Q674L1272 (2TH11702224)1
T8141A1006
T8300A1037/Q6300A1044 (2ET11700124A)
T8300A1144/Q6300A1044 (6ET11700124A)
T8611R1018 (025-27655)
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1217
T8611R1000
T8611G1004
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Configure O/B (select models) in Installer Setup.
B
When W2 is not used, configure W2 cycle rate to NC.
C
Terminal is for multiple auxiliary heat loads such as contactors, sequencers,
or relays.
D
LED is energized when terminal is powered.
E
L terminal is powered continuously in Em. Ht. position.
F
Tape off. Not used.
G
Field-installed E to W2 jumper for improved performance in emergency heat.
Common
H
Power
Compressor
1st Stage
Heat
Auxiliary
Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
EM. Heat
Multiple Aux.
Heat Loads
C
LED
Indication
2nd Stage
Compressor
2nd Stage
Cool
M13224
H
Terminal must be connected to the transformer common.
I
Do not remove factory-installed jumper.
J
Optional Check LED on T8611G1004. See Fig. 26.
K
Field-installed X2 to X (C) jumper.
L
H terminal is not available on all models.
M
Using these thermostats with a W8045 Demand Defrost Control may cause
customer complaints. If replacing a thermostat used on a W8045, see
York/Borg Warner Direct Replacements.
I
I
I
I
A
A
A
A
A
A
I
B
D
E
D
E
D
B
I
I
D
D
B
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
Y
or
Y1
Y
Y
Y1
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W1
W1
W1
W
or
W2
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
H
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
X
L
X1
L
L
L
L
L
L
E
or
X
E
E
E
E
E
E
E
E
E
W3
W3
W3
T
X
X2
X2
X1
X2
X1
X2
W2
Y2
G
G
G
G
G
G
G
G
G
E
F
L
K
K
J
I
Chronotherm
IV
Y594R1425
Y594G1419
Y594G1476