Honeywell Heat/1Cool User Guide - Page 72

Intertherm/miller/nordyne

Page 72 highlights

INTERTHERM/MILLER/NORDYNE Electromechanical Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1308 Y594R1797 Y594G1633 T8T6816111G1R0100400 T8T481411R11R0120802 T8T581511G11G0140721 T8T081011R11R0110406 T8T681611G12G0220802 W890P0CB8190000/2 Existing Function Terminals Common ¿ X X X X Power R R R R Compressor Y Y Y Y 1st Stage - Heat - - - Aux. Heat W2 Fan G W2 W2 W2 º G G G C/O Valve W1 B B B Heat C/O Valve - Cool System Z Monitor O » L O » L O » L Em. Heat K E E E LED Indication - - - - 2nd Stage - Compressor - - - 2nd Stage - Cool - - - ³ Configure O/B (select models) in Installer Setup. · When W2 is not used, configure W2 cycle rate to NC. » LED is energized when terminal is powered. ¿ Terminal X (C) must be connected to transformer common. ´ Do not remove factory-installed jumper. C R or Y1 Y ´ W1 W2 º G B O ¶ L C R Y ´ W1 C R Y1 ´ W1 W2 W2 º G B º G ᕡ or B O/B ᕡ or O O O/B ¶ L » L C C C R Y ´ W1 R R Y1 ´ W1 Y1/W1 - W2 º G B O W2 º G ᕡ or B O/B ᕡ or O O/B · Aux. º G ᕡ O/B ᕡ O/B ¶ » » L L L E E E X1 X2 ² - - - - - E E E - X1 X2 - · - - W2 - - - - - Y2 ² Optional LED indication activated with completed circuit on X1 and X2 terminals. ¶ L terminal is powered continuously when thermostat is in Em. Ht. position. º To eliminate auto fan in emergency heat mode, add switching relay as shown on page 9. M13191 70-6627 • 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
70
INTERTHERM/MILLER/NORDYNE
Common
D
Power
Compressor
1st Stage
Heat
Aux. Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System
Monitor
Em. Heat
LED
Indication
2nd Stage
Compressor
2nd Stage
Cool
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1308
Y594R1797
Y594G1633
T8611R1000
T8611G1004
T8411R1002
T8411R1028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Configure O/B (select models) in Installer Setup.
B
When W2 is not used, configure W2 cycle rate to NC.
C
LED is energized when terminal is powered.
D
Terminal X (C) must be connected to transformer common.
E
Do not remove factory-installed jumper.
M13191
F
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
G
L terminal is powered continuously when thermostat is in Em. Ht. position.
H
To eliminate auto fan in emergency heat mode, add switching relay as
shown on page 9.
1
1
1
C
E
E
E
E
E
C
C
1
1
1
B
C
G
G
C
G
X
X
X
X
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
Y
Y
Y
Y
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W2
W2
W2
W2
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
W1
B
B
B
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
Z
L
L
L
L
L
L
L
L
L
K
E
E
E
E
E
E
E
E
E
X1
X2
X1
X2
W2
Y2
H
H
C
H
H
H
H
H
T8511G1021
T8511G1047
T8611G2002
T8611G2028
B
F
Chronotherm
IV