Honeywell Heat/1Cool User Guide - Page 109

Typical 2-speed Pump

Page 109 highlights

Electromechanical Chronotherm® III WESTINGHOUSE TYPICAL 2-SPEED PUMP Electronic Replacement or Upgrade Chronotherm IV Q6T7³844F1D0121265 T8611M7008 T8511M1002 T8T6816111M2M0220517 W89P00C8B910000/2 Function Existing Terminals Common ¿ X X1 Power R 1st Stage Heat - Compressor Stage 1 Y1 Compressor Stage 2 Y2 2nd Stage Heat - Auxiliary 3rd - Stage Heat R W1 » Y1 Y2 ² W2 - Fan G G C/O Valve O O Cool C/O Valve B Heat System Monitor/ L System Defrost » º X2 Em. Heat W E LED Indication - - ³ When subbase system switch is in AUTO position, equipment will operate in COOL mode only. · IMPORTANT: Do not use T874D/Q674F1022 if B terminal is used on original equipment. » Y1 to W1 jumper required. ¿ Terminal must be connected to the transformer common. C C R R - - Y Y1 Y2 Y2 ² W2 - W3 W3 C C R R - - Y1 Y1/W1 Y2 Y2 ² - W2 W3 Aux. G O B ¾ L G ¶ O/B ¶ O/B º L G ¶ O/B ¶ O/B ¾ L G ¶ O/B ¶ O/B º L E E ´ X1 X2 - E E X1 X2 ´ - ´ Optional LED indication activated with completed circuit on X1 and X2 terminals. ² Y2 to W2 jumper required. ¶ Configure O/B (Select Models) in Installer Setup. º LED is energized when terminal is powered. ¾ L terminal is powered continuously when thermostat is in Em. Ht. position. M13242 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER T872G1356/Q672L1219 T874D,G/Q674L1223 70-6627 • 107

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
107
WESTINGHOUSE
TYPICAL 2-SPEED PUMP
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER
T872G1356/Q672L1219
T874D,G/Q674L1223
T8611M2017
T8611M2025
Function
Existing
Terminals
T8611M7008
T8511M1002
Chronotherm
®
III
Electronic Replacement or Upgrade
Common
D
Power
1st Stage Heat
Compressor Stage 1
Compressor Stage 2
2nd Stage Heat
Auxiliary 3rd
Stage Heat
Fan
C/O Valve
Cool
C/O Valve
Heat
System Monitor/
System Defrost
Em. Heat
LED Indication
M13242
G
G
A
When subbase system switch is in AUTO position, equipment will
operate in COOL mode only.
B
IMPORTANT:
Do not use T874D/Q674F1022 if B terminal is used on
original equipment.
C
Y1 to W1 jumper required.
D
Terminal must be connected to the transformer common.
E
Optional LED indication activated with completed circuit on X1 and
X2 terminals.
F
Y2 to W2 jumper required.
G
Configure O/B (Select Models) in Installer Setup.
H
LED is energized when terminal is powered.
I
L terminal is powered continuously when thermostat is in Em. Ht. position.
PC8900/
W8900B1002
Electromechanical
T84D1165
Q674F1022
A
H
E
E
G
G
I
G
H
H
G
I
C
X
X1
C
C
C
C
R
R
R
R
R
R
W1
Y1
Y1
Y
Y1
Y1
Y1/W1
Y2
Y2
Y2
Y2
Y2
Y2
W2
W2
W2
W3
W3
W3
Aux.
G
G
G
G
G
G
O
O
O
O/B
O/B
O/B
B
B
O/B
O/B
O/B
L
X2
L
L
L
L
W
E
E
E
E
E
X1
X2
X1
X2
F
F
F
C
Chronotherm IV