Honeywell Heat/1Cool User Guide - Page 99

Trane/american Standard

Page 99 highlights

Electromechanical TRANE/AMERICAN STANDARD DIRECT TRADE REPLACEMENTS Chronotherm® III Electronic Replacement or Upgrade Chronotherm IV T841A1555 Y594R1763 Y594G1161 T8T681611G11R0100400 T8T481411R11R0120802 T8T5815111G1G0140721 T8T081011R11R0110406 T8T6816111G2G0220802 W890P0CB8190000/2 Function Existing Terminals Common ³ B B B B C C C C C C Power R R R R R R R R R R Compressor Y Y Y or Y Y1 Y Y Y1 Y Y1 Y1/W1 » » » » » 1st Stage - - - - W1 Heat W1 W1 W1 W1 - ² Aux. Heat W or W1 W W W W2 W2 W2 W2 W2 Aux. Fan G G G G C/O Valve - - - - Heat C/O Valve O O O O Cool System Monitor/ F System Defrost ¶ ¶ ¶ F F F Outdoor or T A T T T Sensor » G B O º L · G G or ´ B B O/B or ´ O O O/B º ¶ L L G G or ´ B B O/B or ´ O O O/B º ¶ L L G ´ O/B ´ O/B ¶ L · · · · · Outdoor Stat X2 X2 X2 X2 E E E LED Indication - - - - X1 X2 ¿ - - 2nd Stage - - - - - - - Compressor E E E - X1 X2 ¿ - ² - - W2 2nd Stage - - - - - - - - - Y2 Cool ³ Terminal must be connected to the transformer common. · Tape off. Thermostat replaces outdoor reset with improved zero droop performance. » Do not remove factory-installed jumper. ¿ Optional LED indication with completed circuit on X1 and X2 terminals. ´ Configure O/B (select models) in Installer Setup. ² When W2 is not used, configure W2 cycle rate to NC. ¶ LED is energized when terminal is powered. º L terminal is powered continuously when thermostat is in Em. Ht. position. M13225 TYPICAL THERMOSTATS AND SUBBASES - HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER) T841A1407 (ASYSTAT652) T874R1939 (ASYSTAT-651A)/Q674L1801 (THT1225) T841A1530 (ASYSTAT652A) T8141A1014 T872G1059/Q672J1039 T8141A1071 T872R1057/Q672L1037 T8300A1128/Q6300A1101 (BAY28X194/BAY28X195) T874G1204/Q674J1043 T8611G1038 (THT-0603) T874G1675/Q674J1142 (ASYSTAT650/WY28X0250) T8611G1111 (TAYSTAT501) T874R1053/Q674L1140 T8611R1091 T874R1426/Q674L1496 (BAYSTAT339/WY28X0112) T8611R1109 (THT-0602) T874R1657/Q674L1611 (ASYSTAT651/WY28X235) T8611R1117 (ASYSTAT700) 70-6627 • 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

70-6627
97
TRANE/AMERICAN STANDARD
DIRECT TRADE REPLACEMENTS
Common
A
Power
Compressor
1st Stage
Heat
Aux. Heat
Fan
C/O Valve
Heat
C/O Valve
Cool
System Monitor/
System Defrost
Outdoor
Sensor
C
Outdoor Stat
LED
Indication
2nd Stage
Compressor
2nd Stage
Cool
T8011R1006
T8011R1014
Function
Existing
Terminals
T841A1555
Y594R1763
Y594G1161
T8611R1000
T8611G1004
T8411R1002
T8411R1028
T8511G1021
T8511G1047
T8611G2002
T8611G2028
PC8900/
W8900B1002
Electromechanical
Chronotherm
®
III
Electronic Replacement or Upgrade
A
Terminal must be connected to the transformer common.
B
Tape off. Thermostat replaces outdoor reset with improved zero droop
performance.
C
Do not remove factory-installed jumper.
D
Optional LED indication with completed circuit on X1 and X2 terminals.
M13225
E
Configure O/B (select models) in Installer Setup.
F
When W2 is not used, configure W2 cycle rate to NC.
G
LED is energized when terminal is powered.
H
L terminal is powered continuously when thermostat is in Em. Ht. position.
B
B
B
B
B
G
F
B
F
B
B
B
B
C
C
C
C
C
C
R
R
R
R
R
R
R
R
R
R
Y
Y
Y
Y
Y1
or
Y
Y
Y1
Y
Y1
Y1/W1
W1
W1
W1
W1
W1
W
or
W1
W
W
W
W2
W2
W2
W2
W2
Aux.
G
G
G
G
G
G
G
G
G
G
B
B
B
or
O/B
B
B
or
O/B
O/B
O
O
O
O
O
O
O
or
O/B
O
O
or
O/B
O/B
F
F
F
F
L
L
L
L
L
L
T
or
A
T
T
T
X2
X2
X2
X2
E
E
E
E
E
E
X1
X2
X1
X2
W2
Y2
C
C
C
C
C
G
G
H
D
D
G
G
H
G
H
E
E
E
E
E
E
Chronotherm
IV
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
T841A1407 (ASYSTAT652)
T841A1530 (ASYSTAT652A)
T872G1059/Q672J1039
T872R1057/Q672L1037
T874G1204/Q674J1043
T874G1675/Q674J1142 (ASYSTAT650/WY28X0250)
T874R1053/Q674L1140
T874R1426/Q674L1496 (BAYSTAT339/WY28X0112)
T874R1657/Q674L1611 (ASYSTAT651/WY28X235)
T874R1939 (ASYSTAT-651A)/Q674L1801 (THT1225)
T8141A1014
T8141A1071
T8300A1128/Q6300A1101 (BAY28X194/BAY28X195)
T8611G1038 (THT-0603)
T8611G1111 (TAYSTAT501)
T8611R1091
T8611R1109 (THT-0602)